TROUBLESHOOTING & REPAIR

F-14

WIRE-MATIC 250

STATIC SCR RECTIFIER ASSEMBLY TEST (CONTINUED)

TEST PROCEDURE

1.

Disconnect main AC input power to
the machine.

2.

Disconnect Plugs J3 and J6 from
the G2332 Control Board. This
electrically isolates the SCR bridge
assembly. See Figure F.2.

FIGURE F.2 - Remove Plugs J3 and J6
to Perform Static SCR Rectifier
Assembly Test.

3.

Verify that the capacitors have com-
pletely discharged with an Analog
Volt-Ohm meter.

4.

Disconnect leads X2 and X3 from
the negative capacitor bank using a
1/2" open end wrench. See Figure
F.3.

FIGURE F.3 - Location of Leads X2
and X3.

5.

Separate leads X2 and X3 from the
negative capacitor bank buss bar.
Be sure there is no electrical con-
tact. See Figure F.3.

LEADS
X2 AND X3

NEGATIVE
CAPACITOR
BANK
BUSS BAR

G2332

WM-250 CONTROL

J2

J7

J4

J10

J6

J9

J3

J5

J1

REMOVE
PLUGS J3 & J6