Workstation Problems

Most non-cabling problems result from improper configuration of the network
interface card (NIC) and its corresponding driver. The following points will be
helpful:

Like other add-on cards in the workstation or server, NIC must have unique

memory address, I/O address, and interrupt. The settings on a particular card
must not conflict with the settings on any other card in the same station.
Please refer the User's manual of the NIC, computers, and Networking
operating systems to determine the proper configuration

The selection of half or full duplex, the speed of 10 or 100Mbps for the NIC

setting must match the mode and speed setting of the corresponding port of
the Hub. For NWay Auto-Negotiation setting, both link partners will auto-adjust
to the highest allowable speed and mode operation

Other Problems

Other specific problems may be diagnosed by using the LEDs, as below.
Power LED is off when the AC Power switch is ON:

• Defective power supply unit or fuse

• Incorrect AC voltage

• Defective Hub

Link/Act LED is off at any Fiber:

• Faulty node or wiring connection

For fiber - the "TX", "RX" cables should be paired at both ends
No Link signal is received from the remote node/site

100Base-X Port at irregular traffic:

• Abnormal or invalid transmission status(mode / speed) between local and

remote link partners, i.e., full-duplex port is connecting to a half-duplex port,
or 10Mbps port is connecting to a 100Mbps device

Hub Diagnostic Test

 The switch hub performs self-diagnostic test at major hub modules upon

power on, LED indicators will go to normal status if no problem occurred

 To reset or restart the hub, power off the hub and wait for 10 seconds, then

power on it again