INSTALLATION

SQUARE WAVE TIG 175

1

TECHNICAL SPECIFICATIONS - Square Wave TIG 175 (K1583-1 only)

For AC/DC Stick and DC TIG Welding at 150A/25%

Duty Cycle and for AC TIG Welding up to

110A/25% Duty Cycle. Based on the 1996 U.S.

National Electrical Code

For AC TIG Welding at 150 A/25% Duty

Cycle, Based on the 1996 U.S. National

Electrical Code

Code

Number

10457

Volts at Rated Amperes

16.0 V AC/DC
15.0 V AC/DC
14.4 V AC/DC
13.4 V AC/DC

26.0 V AC/DC
25.0 V AC/DC
24.4 V AC/DC
23.4 V AC/DC

Type of Output

CC (Constant Current)

AC/DC

Input Current at

Rated Output

54/33/30 AC/DC Stick & DC TIG, 71/41/37 AC TIG

54/30 AC/DC Stick & DC TIG, 71/37 AC TIG

Amps

150
125
110

85

150
125
110

85

Maximum Open

Circuit Voltage

(STICK AND TIG)

AC OCV: 78

DC OCV: 64

Standard

Voltage

240/380/415/1/50/60

Additional Lincoln Rating 220-240/400-415/1/50/60

Duty Cycle

GTAW 25% Duty Cycle

40% Duty Cycle
60% Duty Cycle

100% Duty Cycle

SMAW 25% Duty Cycle

40% Duty Cycle
60% Duty Cycle

100% Duty Cycle

Output Current

Range

10-175 Amps

AC and DC

INPUT - SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES

(1)

Input

Voltage /

phase/

Frequency

240/1/50

380/1/50

415/1/50

220/1/50

400/1/50

Input

Ampere

Rating on

Nameplate

54

33

30

54

30

Type 75

°

C

Copper Ground

Wire in

Conduit AWG

(IEC) Sizes

10 (5.2 mm2)

14 (2.1 mm2)

14 (2.1 mm2)

10 (5.2 mm2)

14 (2.1 mm2)

Fuse

(Super Lag)

or Breaker

Size

100

60

60

100

60

Type 75

°

C

Copper Wire in

Conduit AWG

(IEC) Sizes

10 (5.2 mm2)

14 (2.1 mm2)

14 (2.1 mm2)

10 (5.2 mm2)

14 (2.1 mm2)

Type 75

°

C

Copper Ground

Wire in

Conduit AWG

(IEC) Sizes

8 (8.2 mm2)

12 (3.3 mm2)

12 (3.3 mm2)

8 (8.2 mm2)

12 (3.3 mm2)

Type 75

°

C

Copper Wire in

Conduit AWG

(IEC) Sizes

8 (8.2 mm2)

12 (3.3 mm2)

12 (3.3 mm2)

8 (8.2 mm2)

12 (3.3 mm2)

Input

Ampere

Rating on

Nameplate

71

41

37

67

37

Height

Width

Depth

Weight

Power

19.53 in.

13.72 in.

24.94 in.

Approx. 200 lbs.

Source

496 mm

349 mm

633 mm

90.9 kgs.

Power Source

27.93 in.

19.22 in.

36.74 in.

Approx. 230 lbs.

on

709 mm

488 mm

933 mm

105 kgs.

Undercarriage

PHYSICAL DIMENSIONS

Fuse

(Super Lag)

or Breaker

Size

125

80

70

125

70

(1)

The National Electrical Code permits operation at rated output and duty cycle from a 50 amp receptacle when supply lines and fuses are sized per this table.