3 electrical parts – LG 230/208V User Manual

Page 12

Advertising
background image

—12—

2.2.3 SHROUD

1. Remove the fan. (Refer to section 2.2.2)
2. Remove the screw which fastens the shroud.
3. Remove the shroud. (See Fig. 8)
4. Re-install the component by referring to the

removal procedure, above.

2.3 ELECTRICAL PARTS

2.3.1 OUTDOOR MOTOR

1. Remove the clamp cord and disconnect a wire

housing in control box. (Refer to section 2.1.2)

2. Remove the fan. (Refer to section 2.2.2)
3. Remove the 2 screws which fasten the motor.

(See Fig. 9)

4. Remove the motor.
5. Re-install the components by referring to the

removal procedure, above.

2.3.2 INDOOR MOTOR

(Refer to section 2.2.1)

2.3.3 COMPRESSOR

1. Discharge the refrigerant system using Freon

TM

Recovery System.
If there is no valve to attach the recovery system,
install one (such as a WATCO A-1) before venting
the Freon

TM

. Leave the valve in place after

servicing the system.

2. Disconnect the 3 leads from the compressor.
3. After purging the unit completely, unbraze the

suction and discharge tubes at the compressor
connections.

4. Remove the 3 nuts and the 3 washers which

fasten the compressor. (See Fig. 10)

5. Remove the compressor.
6. Re-instill the components by referring to the

removal procedure, above.

2.3.4 CAPACITOR

1. Remove the control box. (Refer to section 2.1.2)
2. Remove 1 screw and disconnect the leads which

connected to the box type capacitor.
(See Fig. 11)

3. Remove 1 screw and the clamp which fastens the

can-type capacitor. (See Fig. 11)

4. Disconnect all the leads of capacitor terminals.
5. Re-install the components by referring to the

removal procedure, above.

Figure 8

Figure 9

Figure 10

Figure 11

Advertising