LTR-GPS Installation and Setup Guide

4. Set Daylight Savings Time switch 3 according to the following table to enable

U.S. rules: 2:00AM first Sunday in April and last Sunday in October:

Daylight

Savings

SWITCH

3

Enable

OPEN

Disable

Closed


5. Switch 2 is used for custom ordered protocols only. This should normally

be left in the OPEN position.


6. If using the RS232 port (requires cable # SAE0370, sold separately) to

transmit a plain text “time stamp”, OPEN switch 1 to select Local Time
transmission. Close switch 8 to transmit GMT.

RS-232

Time Stamp

SWITCH

1

Local Time

OPEN

G.M.T.

Closed

Format for ASCII output: “MM-DD-YYYY HH:MM:SS cr”.
Communications Port Settings: 9600, N, 8, 1

7. Re-align and gently flex apart the cover to replace it over the chassis, making

sure that the circuit board connectors protrude through the appropriate side
cut-outs. Secure the cover with the four (4) screws previously removed.