Lincoln Electric MC-706 User Manual

Metalshield, Mc-706, Mild steel metal-cored wire

Advertising
background image

DIAMETERS/PACKAGING

500 Lb. (227 kg)

Diameter

33 Lb. (15 kg)

50 Lb. (23 kg)

50 Lb. (23 kg)

Accu-Trak™

in. (mm)

Steel Spool

Fiber Spool

Coil

Drum (20 in.)

.045 (1.2)

ED031583

ED031586

ED031589

ED031592

.052 (1.3)

ED031584

ED031587

ED031590

ED031593

1/16 (1.6)

ED031585

ED031588

ED031591

ED031594

Metalshield

MC-706

Mild Steel Metal-Cored Wire

(AWS E70C-6M H8)

When you’re welding heavy-duty materials in demanding environments like structural steel, heavy equipment,
agricultural, or automotive component manufacturing, you need a highly productive wire. Metalshield MC-706
is built for productivity throughout the welding process. MC-706 even welds well over mill scale to reduce
prep time. A stiff sheath aids in improving the feedability of the wire, and few metal-cored products compare
in terms of bead shape and appearance. Not only does MC-706 reduce the amount of silicate islands, it also
moves the silicate islands away from the toes and into the center of the bead, making it easier to remove the
silicon and minimize cleanup time.

Advantage Lincoln

• Minimal silicate islands – reduces/eliminates cleaning.

• Silicate placement away from the toes of the weld – makes

removal easier/makes it easier to visually inspect weld.

• Excellent wash-in and bead appearance – enhances weld

bead appearance and improves overall weld quality.

• Stiffer sheath – excellent feedability.

• Excellent performance over mill scale – reduces joint

preparation time.

• Minimal spatter when welding over mill scale – can reduce

cleaning time.

• ISO14001 and 9001 certified – manufactured to standards for

environmental and quality management systems.

Welding Positions

Typical Applications

• High speed fillet welds on lap and T-joints.

• Robotic and hard automation.

• Weldments over mill scale where spatter must be minimized.

• Weldments that are coated after welding.

• Weldments where weld quality, weld productivity, and weld

appearance are of utmost importance.

• Out-of-position welding can be done with a pulsed spray or

short-arc welding procedure.

Shielding Gas

75-92% Argon / Balance CO2

Flow Rate: 40-60 CFH
Not recommended for use with 100% CO2.

Conformance

AWS A5.18-01: E70C-6M H8
ASME SFA-5.18: E70C-6M
CWB/CSA: E492C-6M-H8

Diffusible Hydrogen -

As required per AWS A5.18-01

(mL /100g weld deposit), 75% argon/25% CO2 shielding gas

Requirements (AWS E70C-6M H8):

<8

Test Results:

3-5

1F

1G

2F

2G

Charpy V-Notch

Yield Strength

Tensile Strength

Elongation

ft•lbf (Joules)

psi (MPa)

psi (MPa)

(%)

@ -20ºF (-29ºC)

Requirements
AWS E70C-6M H8

58,000 (400)

70,000 (483)

22

20 (27)

As Welded

min.

min.

min.

min.

Test Results

59,000–62,800

72,500–77,400

25–29

27–48

75% Ar/25% CO2

(407–433)

(500–534)

(37–65)

MECHANICAL PROPERTIES – As Required per AWS A5.18-01

Publication C3.11.2 1/06

www.lincolnelectric.com

CORED WIRE

Advertising