Advanced features, Setting the time of day, Temperature override and temperature hold – Lux Products TX9000 User Manual

Page 4: Energy usage monitor, Filter usage monitor, Rotate the dial back to the run position, Rotate the dial to set day/time, Dial must be in the energy usage position

Advertising
background image

To change current day.

Open the drop down door on the front of the thermostat. Rotate the dial to the

SET DAY/TIME position. You should see the display pictured above with a day of
the week flashing. When you are finished setting the day and time, rotate the dial
to RUN to return to normal operation or to another position to continue
programming.

C

A

U

T

I

O

N

The unit is protected against normal static electric discharges. However, in

extremely dry weather you should touch another metal object before the unit

to avoid potential loss of programs.

To change the current time.

To set current time. The (e.g.
“12:00”) will be flashing.

To program temperature.

To change the start
time for MORN.

To move to DAY.

To change the temp.
setting for MORN.

To program temperature.

To change start time
for DAY.

To move to EVE.

To change the temp.
setting for DAY.

To program temperature.

To change the start
time for EVE.

To move to NIGHT.

To change the temp.
setting for EVE.

To program temperature.

To change the start
time for NIGHT.

To change the temp.
setting for NIGHT.

Rotate dial to SET WEEKDAY PROGRAM. To
program SATURDAY or SUNDAY, rotate the dial to
SET SATURDAY or SET WEEKEND PROGRAM.
With dial on SET WEEKDAY PROGRAM, you will
see this display.

TEMP

TU

AM

MORN

HEAT

PROGRAM

FOR:

MO

WE TH FR

START AT:

SET TEMP

NEXT

UP

DOWN

NEXT

UP

DOWN

NEXT

UP

DOWN

NEXT

NEXT

UP

UP

UP

DOWN

DOWN

NEXT

UP

DOWN

NEXT

UP

DOWN

NEXT

UP

DOWN

UP

DOWN

SETTING THE TIME OF DAY

The COPY button can be used to duplicate

the programs from any previous day.

Rotate dial to RUN position to start the programs or SET

WEEKEND PROGRAM to continue programming.

Press UP/DOWN to change the current temperature setting. The
OVERRIDE indicator appears on display. The Override feature
will be automatically canceled at the start of the next program
period. To cancel OVERRIDE prior to next program period press
UP/DOWN until original set temperature appears. OVERRIDE
indicator will disappear from display.

TEMPORARY TEMPERATURE OVERRIDE

VACATION TEMPERATURE HOLD

TEMPERATURE OVERRIDE AND TEMPERATURE HOLD

These features let you change the current Set Temperature without changing the

programs stored in your thermostat’s memory.

DOWN

UP

Press HOLD. Adjust temperature as desired with UP/DOWN.
Temperature setting will not change even after next program
period begins. To clear, press HOLD again.

HOLD

ADVANCED FEATURES

ENERGY USAGE MONITOR

A timer in the unit records your systems’s ON time for the current day, the

previous day, and cumulatively to let you see the effects of your temperature
settings and weather conditions.

TEMPERATURE SWING

A thermostat works by turning your heating or cooling system on and off

whenever the room temperature varies a certain number of degrees from the
set-point temperature. This variation is the “swing.” Your system should cycle
on about 3 to 6 times per hour. A smaller swing number increases the number
of cycles, so room temperature is more constant. A larger swing number
decreases the number of cycles, to save energy in most cases.

FILTER USAGE MONITOR

The FILTER Monitor counts the hours since the filter in your blower was last

changed. After 250 hours of use, FILTER will appear in the display. After you
change the filter, set the thermostat’s FILTER Monitor back to zero as follows.

TEMPERATURE CALIBRATION

SWING SETTINGS

PROGRAM LOCK

To change the FILTER Usage Monitor limit

To reset the counter

Rotate the dial to FILTER

To disable the FILTER Usage Monitor set the limit to 0 hours

To change the limit
from 0-500 hours

Rotate the dial to SET DAY/TIME

Press together

To adjust the thermostat

To prevent tampering with set
programs. The sequence of keys
to lock and unlock the program:

Hold for two seconds

Dial must be in the ENERGY USAGE position

Press together

To change the temp.

swing between 1-9

(4= approx. ±1°F)

Press to set.

NEXT

NEXT

HOLD

NEXT

NEXT

HOLD

NEXT

UP

DOWN

UP

DOWN

UP

DOWN

UP

DOWN

NEXT

NEXT

HOLD

•Select HEAT to monitor heating energy usage or COOL to

monitor cooling usage.

•Rotate the dial to SET ENERGY/USAGE

The current day’s ENERGY usage is displayed.

To reset the display to zero.

To display yesterday’s

energy use.

NEXT

UP

To undo the previous

reset to zero.

UP

To display total ENERGY

usage since the Monitor

was last set to zero.

NEXT

Rotate the dial back to the RUN position.

4

Advertising