MATERIAL SAFETY DATA SHEET


Page 2 of 3 CP-269

Section 6: Accidental Release Measures


Spill / leak Procedures: If spilled, sweep up using an approved toner vacuum with a 0.5 micron filter or smaller, such as the Atrix
AAA Toner Vacuum or 3M Toner Vacuum. Use of a vacuum cleaner not rated for toner particles, could result in a fire or personal
injury. Remove residue with soap and cold water.
Miscellaneous: Keep product out of sewers and watercourses.
Personal protection: Avoid inhalation of dust.

Section 7: Handling and Storage


Special Handling:


Cleanse skin after contact before breaks or meals, and end of workday.
Do not handle in areas where the wind blows.
Minimize the breathing of dust.

Special Storage:

Avoid direct sunlight. Keep out of reach of children. Store in a cool, dry place. Below 35C (95F)

Section 8: Exposure Control and Personal Protection Information:


Respiratory Protection: none required under normal use. Hand Protection: none required under normal use.

Eye Protection: none required under normal use. Skin Protection: none required under normal use.

Section 9: Physical and Chemical Properties

CHARACTERISTICS:
Appearance: Black

Softening

point:

110-150

°C

Form: Powder

Vapor

pressure:

N/a

Odor: Odorless

Vapor

density:

N/a

Solubility in Water:

Negligible

Evaporation rate:

N/a

Specific gravity:

N/a

Boiling point:

N/a

Density:

1.1 – 1.5 g/cm

3

% Volatiles:

N/a

Section 10: Stability and Reactivity


Conditions to avoid:

None

Materials to avoid:

None

Hazardous decomposition products:

CO, CO2, and NOx when burned.

Stability:

Stable

Section 11: Toxicological Information:


Ames test:

Negative

Acute oral toxicity: Rat:

LDLO: 5.0g/kg

Special effects: Carcinogenicity: In 1996 the IARC reclassified Carbon Black as a Group 2B carcinogen (possible human
carcinogen). This evaluation is given to carbon black for which there is inadequate human evidence, but sufficient animal
evidence. The latter is based upon the development of lung tumors in rats receiving chronic inhalation exposures to free carbon
black at levels that induce particle overload of the lung. Studies performed in animal models other than rats have not
demonstrated an association between carbon black and lung tumors. Moreover, 2-years cancer bioassay using a typical toner
preparation containing carbon black did not demonstrate an association between toner exposure and tumor development in rats.
Teratogenicity: Not available

Section 12: Environmental / Ecological Information


Bioaccumulation:

Not known

Environmental Degradability:

Not known

Section 13: Disposal Consideration


Used toner should be disposed of under conditions that meet all federal, state and local environmental regulations. Do not
incinerate loose or spilled toner.









In

formation on this data sheet represents our current data and best opinion as to the proper use in handling of this product under

rmal conditions.

On the basis of the data available to us, this product is not a dangerous substance. One should, however, observe the