Operation, Welding operations, Sequence of operation – Lincoln Electric IM788 User Manual

Page 16: Figure b.1b

Advertising
background image

B-3

B-3

OPERATION

FIGURE B.1a

4. Circuit Breaker – Protects machine from damage if

maximum output is exceeded. Button will extend
out when tripped (Manual reset).

5. Gun Trigger - Activates welding output, wire feed,

and gas solenoid operation. Releasing the trigger
deactivates welding and simultaneously activates
the “burnback” function so that the welding wire
does not stick in the weld puddle. See FIG B.1b

WELDING OPERATIONS

SEQUENCE OF OPERATION

Wire Loading
Refer to Figure B.2 AND B3.

The machine power switch should be turned to the
OFF (“O”) position before working inside the wire feed
enclosure.

The machine is shipped from the factory ready to feed
4” (100 mm) diameter spools. A 4" (100 mm) diameter
spool is mounted directly on the 5/8" (16 mm) diame-
ter spindle that has a built-in adjustable friction brake
to prevent overrun of the spool and excess slack in
the wire. The wing nut at the end of the shaft is used
to adjust the tension on the wire spool (See B.3 on the
following page).

To use 8" (200 mm) diameter spools, the 2" (51 mm)
diameter M15445 spindle must be used. Remove the
spacer and wing nut at the end of the shaft. Insert
spindle as shown in figure B.2. Reattach spacer and
wing nut.

Note: When loading and removing the 8” Spools
make sure that the wing nut (inside the wire spool
spindle hub) is turned 90° from the wire spool spindle
locking tab. If the wing nut is positioned in line with the
locking tab, the tab cannot be depressed to load or
unload the wire spool.

Make certain the start end of the wire, which may pro-
trude through the side of the spool, does not contact
any metallic case parts.

FIGURE B.2

1

1

SP-135 Plus

WELDING AMP RANGE

WELDING AMP RANGE

25-125

25-125

3

2

+

-

5

Wire Spool must be pushed all the way on the spindle

so that the spindle’s tab will hold it in place. The Wire

Spool must rotate clockwise when wire is dereeled.

To wire drive

Be sure that this stud engages
the hole in the wire spool.

8” Wire Spool

Wire Spool Spindle

Locking Tab

FIGURE B.1b

SP-135 PLUS

Advertising