Lightolier 3R User Manual

Is:3r

Advertising
background image

;;;

;;;

;;;

;

;

JUNCTION BOX

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE

This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720

INSTRUCTION SHEET NO.

IS:3R

C0400 Page 1 of 1

INSTALLATION PROCEDURE FOR REMODELER KITS

2003R (3 3/4”), 1003R (5”), 1103R (6 3/4”)

FOR USE WITH LYTECASTER 2000 SERIES, 1000 SERIES OR 1100 SERIES TRIMS (FINISHING SECTIONS) ONLY

1. CUT OPENING

Use aperture sticker provided as a template to cut a hole in the
ceiling. Cut to outside edge of sticker.

;;;;

WARNING: (RISK OF FIRE) DO NOT INSTALL INSU-
LATION WITHIN 3” OF FIXTURE SIDES OR WIRING
COMPARTMENT, NOR ABOVE FIXTURE IN SUCH A
MANNER SO AS TO ENTRAP HEAT.

NON-METALLIC

SHEATHED CABLE

(12 or 14 gauge only)

CABLE
CLAMP

;;

;;

MOUNTING CLIP

MOUNTING RING
FLANGE

2. ATTACH MOUNTING RING

Push MOUNTING RING into opening until FLANGE sits against
ceiling making sure “J-BOX” SLOT is in a position that will
ensure enough space above ceiling for the J-BOX to sit flat
against ceiling (see Step 4). Slide MOUNTING STRAPS down
to trap ceiling thickness and then bend up to secure.

Note: When installing 2003R, Wire-In and push J-BOX through

ceiling opening before attaching MOUNTING RING.

3. WIRE-IN

With 1103R and 1003R Remodeler Kits, the J-BOX can be
hung temporarily from MOUNTING RING to assist with wire-in.

Open hinged KNOCKOUT to allow NON-METALLIC CABLE to
enter JUNCTION BOX. Push CABLE through CLAMP.

Note: Wiring and connections must not be placed in

JUNCTION BOX in a manner which will interfere
with the CLAMPS action to provide strain relief.

Wire to SUPPLY LEADS. WHITE FIXTURE LEAD to NEUTRAL
SUPPLY LEAD. BLACK FIXTURE LEAD to HOT (120V) SUPPLY
LEAD. BARE FIXTURE WIRE to SUPPLY GROUND. Use wirenuts
(local hardware item). Place all electrical connections in the
J-BOX and close the J-BOX COVER.

4. ATTACH J-BOX

Insert J-BOX MOUNTING STRAP between the ceiling material
and MOUNTING RING and through the “J-BOX” SLOT on the
MOUNTING RING. Pull the STRAP until the J-BOX PLATE sits
flat on the ceiling with the feet over the edge of the ceiling
thickness.
Bend J-BOX PLATE MOUNTING STRAP up to secure.
Make sure that the J-BOX PLATE is securely attached to the
ceiling and the J-BOX is in the position shown.

5. SNAP-ON

6. PUSH-UP

FEET

J-BOX PLATE
MOUNTING STRAP

;;;

;;;

;;;

;;;

;

;

FEET

SEE SEPARATE
REFLECTOR TRIM
INSTRUCTION
SHEETS.

}

®

Advertising