4f23, Architectural decorative, Features – Lightolier Architectural Decorative 4F23 User Manual

Page 2: Lamping (by others), Electrical, Mounting, Labels, Application data, Job information type

Advertising
background image

Job Information

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • D0609

Architectural Decorative

4F23

Page 2 of 2

Pendalux Gemini 23” Diameter Body 2-26/32/42 Triple Tube

Features

1. Diffusing Reflector: White translucent acrylic, 3/16” thick.
2. Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3. Chassis: Steel, 20 gauge, semi-gloss white powder-coat finish.
4. Suspension: Swivel (central) stem, 3/4” steel tube. Canopy, 7” Dia.,

fastened internally, no exposed hardware. Permits installation on ceilings
with slope of up to 45˚. Complies with California Code.

5. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4

lamp base.

6. Flange Trim: Steel 20 gauge, Plated or Painted finish.

Lamping (by others)

Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.

General Electric

Osram/Sylvania

Philips

26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp

F26TBX/*/A/4P

CF26DT/E/IN/*

PL-T26W/*/4P

32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp

F32TBX/*/A/4P

CF32DT/E/IN/*

PL-T32W/*/4P

42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp

F42QBK/*/A/4P

CF42DT/E/IN/*

PL-T42W/*/4P

*Manufacturers’ color temperature designation.

Electrical

Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage
N120/277V, Multi-Wattage 26/32/42W.
4 Lamp

26 Watt

32Watt

42Watt

Voltage

120V 277V 120V 277V 120V 277V

Total Input Watts

55

55

68

68

93

93

Max. Line Current (amps) 2.22

0.96 2.80

1.20 1.20

1.60

Power Factor

>0.98 >0.98 >0.98 >0.98 >0.99 >0.99

Ballast Factor

1.02

1.02 0.96

0.96 0.95

0.95

THD<10% Minimum Starting Temperature: -5°F/-20°C.

Mounting

Mounts directly to 4” outlet box, using crossbar hanger, supplied.

Labels

cULus listed (suitable for damp locations).

Application Data

Reflectances: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75(.88 BF x .85)
FC (footcandles) at 30” work plane.

ZONAL LUMENS AND PERCENTAGES

DATE: OCT. 4, 2000
PREPARED FOR:
LIGHTOLIER, FALL RIVER, MA

ANGLE MEAN CP LUMENS

0

195

5

193

18

10

191

15

189

53

20

184

25

177

82

30

169

35

158

99

40

148

45

137

106

50

126

55

113

101

60

100

65

88

87

70

76

75

64

68

80

53

85

42

47

90

38

CERTIFIED TEST REPORT NO. 4A23242A

COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE

CAT. #4A23242, 23” DIFFUSER

2-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS.

ADVANCE BALLAST #ICF-2S42-M2-LD, 120VAC

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

ANGLE MEAN CP LUMENS

90

38

95

80

121

100

245

105

437

456

110

604

115

735

725

120

848

125

949

848

130

1035

135

1091

842

140

1133

145

1140

713

150

1125

155

1103

507

160

1051

165

956

267

170

812

175

647

65

180

598

C

ANDLEPOWER SUMMARY

DATE: DEC. 11, 2000
PREPARED FOR:
LIGHTOLIER, FALL RIVER, MA

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD

%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

80

70

50

30

10

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

1

.69 .66 .63 .60 .58 .55 .44 .43 .41 .29 .28 .27 .15 .15 .15 .08

2

.60 .55 .51 .53 .49 .45 .38 .36 .34 .25 .24 .23 .13 .13 .12 .07

3

.53 .47 .43 .46 .42 .38 .34 .31 .28 .22 .21 .19 .12 .11 .10 .06

4

.47 .41 .36 .41 .36 .32 .30 .27 .24 .20 .18 .16 .11 .10 .09 .05

5

.41 .35 .30 .36 .31 .27 .27 .23 .20 .18 .16 .14 .09 .08 .08 .04

6

.37 .31 .26 .32 .27 .23 .24 .20 .18 .16 .14 .12 .08 .07 .07 .04

7

.33 .27 .22 .29 .24 .20 .21 .18 .15 .14 .12 .10 .08 .06 .06 .03

8

.30 .24 .20 .26 .21 .17 .19 .16 .13 .13 .11 .09 .07 .06 .05 .03

9

.27 .21 .17 .23 .19 .15 .17 .14 .12 .12 .10 .08 .06 .05 .04 .02

10

.24 .19 .15 .21 .17 .13 .16 .13 .10 .11 .08 .07 .06 .05 .04 .02

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

153

2.40

2.95

0-40

252

3.95

4.86

0-60

459

7.18

8.83

0-90

661

10.34

12.72

40-90

409

6.39

7.86

60-90

202

3.16

3.88

90-180

4543

70.98

87.28

0-180

5204

81.33

100.00

** EFFICIENCY = 81.3% **

23 Inch Diameter
24’ x 24’ x 9.5’ Space
Luminaire

Spacing: 8’ x 8’

Susp. Dist. 24”

2 Lamps

26W

32W

42W

TTT

TTT

TTT

Illum. (FC)

22

29

40

Maint.
Lum.

7/1

7/1

8/1

Ratio
Watts/

0.85

1.06

1.45

Sq. Ft.

Advertising