9. Connect the black wire from the blower

(step 6) to the black rheostat wire. Using a
¼” nut driver, install the rheostat housing
onto the rear shroud using the 2 screws
provided. Ensure that the wires and
connectors are completely through the
hole and contained in the rheostat
housing. See Figure 9.


10. Reinstall rear shroud (reverse step 3 on

page 1).

11. Reconnect the 2 black on/off switch

wires to the valve (TP/TH and TH
terminals). See Figure 1 and Figure 10.

Reconnect burner switch wires.

BLOWER OPERATION:


When the stove heats up, the blower will
automatically turn on at the speed determined
by the rheostat. To adjust the blower speed,
dial the rheostat to the desired speed setting.
Turn the knob clockwise just past the click
(the first ON position) for the highest speed
setting. Turning the knob further clockwise
will provide slower blower speeds. Note: If the
rheostat is not turned “on”, the blower will not
operate.

WARNING: The power cord MUST

BE PLUGGED DIRECTLY INTO A

PROPERLY GROUNDED, 120 VOLT,

60 HZ, 3-PRONG RECEPTACLE

electrical outlet. Do not cut or

remove the grounding prong from

this plug. It must be routed to avoid

contact. Do not route power cord

under or in front of appliance.

INSTALLATION INSTRUCTIONS:

(for units WITH a Full function flame
modulating Remote Control System, H0301
or H0302)


Note: The rheostat assembly, fan disc (with
wire) and the #8 screws will not be used.

1. Install the blower, disconnect the on/off

switch wires and remove the rear shroud
(Follow steps 1, 2 & 3 on page 1).

2. Connect the 2 black wires together from

the blower assembly. See Figure 11 and
14.


3. Stow wires into existing wire holders on

the inside of rear shroud. See Figure 12.


4. Reinstall rear shroud (reverse step 3 on

page 1).


BLOWER OPERATION:
Follow instructions provided with the
modulating remote control kit.

Wiring Diagram (WITHOUT full function modulating remote control kit installed)



BLOWER ASSEMBLY

POWER CORD

M

M

F

F

FAN DISC

RHEOSTAT

WHITE

NOTE:
M = MALE CONNECTOR
F = FEMALE CONNECTOR

BLOWER MOUNTING
BRACKET

WHITE

BLACK

BLACK

BLACK

BLACK

BLACK

M

F

POWER CORD

BLOWER ASSEMBLY

BLOWER MOUNTING
BRACKET

Figure 9

Secure rheostat
housing to
shroud using 2
screws provided

Figure 10

Connect the 2 black wires
together from blower.

Blower

Figure 11

Wiring Diagram (WITH full function modulating remote control kit installed)

Figure 12

F

F

Figure 13

Figure 14

Wire Holders

Advertising