READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE

This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

INSTRUCTION SHEET NO.

IS

:

26556MC Y

0798

Page 1 of 2

INSTALLATION INSTRUCTIONS FOR ATTACHING AND OPERATING

ProSpec

TRACK LIGHTING FIXTURE. FOR JUNCTION BOX MOUNT.

LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720

CANOPY is designed for a 4” octagon OUTLET BOX. FIXTURE can
mount to different OUTLET BOXES as long as box mounting holes
are on 3.5” centers and FIXTURE CANOPY covers box completely.
Box mounting holes should be tapped with 8-32 thread.

1. Thread 8-32 STUDS into J-BOX. STUDS should extend from

J-BOX at least one inch.

2. WHILE SUPPORTING FIXTURE, MAKE CONNECTIONS: B L A C K

FIXTURE LEAD to HOT (BLACK) SUPPLY LEAD; WHITE FIXTURE
LEAD to NEUTRAL (WHITE) SUPPLY LEAD. UNINSULATED
FIXTURE WIRE is a ground and must be connected to G R O U N D
TERMINAL or GROUND LEAD inside OUTLET BOX. Use WIRE
NUTS (local hardware item). Push connections back into
OUTLET BOX.

3. Push CANOPY against ceiling passing STUDS through holes

in CANOPY. Make sure wires are not pinched.

4. Thread 2 CAP SCREWS onto STUDS. Drive CAP SCREWS

until CANOPY is tight against the ceiling.

CAUTION: CAP SCREWS must be completely threaded onto

the S T U D S.

NOTE: The proper L A M P should be installed into the F I X T U R E

prior to energizing. See instructions below.

INSTRUCTIONS FOR ATTACHING FIXTURE TO J-BOX (Fig. 1)

LAMP BOSS

Fig. 1

SNOOT

ACCESS KNOB

LAMP ALIGNMENT
BRACKET

LAMP SPRING

J-BOX

SPADE TERMINAL

RING NOTCH

CAUTION:
• Turn off power at fuse box before installing fixture.
• Fixture temperature is extremely high during operation. Use heat

r e s i d e n t gloves or other heat resistant materials to protect hands
when adjusting or handling the fixture during operation.

• Do not install fixture near combustible materials.
• Fixture is not for residential use.
• Electrical supply to fixture must be 120 volts. Electrical supply

can be AC or DC.

• Do not mount fixture on a wall.

The following lamps may be used in the FIXTURE:

Fixture Cat. No. 26556M, WHCY, BKCY
Lamp

12 Volt PAR 56 Screw Terminal
120 to 240 Watt

1. Holding SNOOT loosen ACCESS KNOB a few turns until

SNOOT opens.

2. Screw SPADE TERMINALS into LAMP TERMINALS.
3. Align 3 LAMP BOSSES with 3 RING NOTCHES. Align LAMP

SCREW TERMINALS with LAMP ALIGNMENT BRACKET.
Push LAMP into FIXTURE until LAMP SPRINGS hold LAMP.
NOTE: The 3 LAMP BOSSES must sit in the 3 RING NOTCHES

after the LAMP is installed.

4. Removing L A M P: Snap LAMP out of L A M PS P R I N G S. Unscrew

LAMP TERMINALS.

LAMPING & USING ACCESSORIES (Fig. 2)

LAMP TERMINAL

Fig. 2

J-BOX

8-32 STUD

BLACK WIRES (Hot)

CANOPY

CAP SCREW

GROUND WIRES

WHITE WIRES
(Neutral)

SWITCH