Only qualified personnel should install, use or service
this equipment.

------------------------------------------------------------------------

Disconnect input power to the extraction system
before installing this equipment.

------------------------------------------------------------------------

INSTALLING THE SENSOR

The K1670-1 Auto Start/Stop Arc Sensor can be
installed with a:

K1669-1 Lamp Kit for a K1653-1 Mobiflex 200-M

OR

K1669-2 Lamp Kit for Wall-Mounted Systems.

OR

K1706-1 Lamp Kit for all other Mobiflex Units

------------------------------------------------------------------------

Remove the switch box (Fig. 1A) by squeezing togeth-
er the front and back. Pull the control board (Fig. 1D)
off the bottom of the switch (Fig. 1B). Disconnect the
lamp cable (Fig. 1C) from the control board using a
small screwdriver.

A-2

INSTALLATION

AUTOMATIC START/STOP ARC SENSOR

A-2

Read this entire installation section before you
start installation.

SAFETY PRECAUTIONS

Do not attempt to use this equipment until you have
thoroughly read all installation, operating and mainte-
nance information supplied with your equipment. They
include important safety precautions and detailed
operating and maintenance instructions.

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts such

as internal wiring.

• Turn the input power off at the fuse box

before working on this equipment.

• Have a qualified person install and ser-

vice this equipment.

------------------------------------------------------------------------

MOVING PARTS can injure.

• Do not operate without extraction arm

installed.

• Keep away from moving parts.

------------------------------------------------------------------------

GENERAL DESCRIPTION

The K1670-1 Automatic Start/Stop Arc Sensor can be
used with the Lamp Kit to automatically switch on the
connected extraction fan when it detects the arc flash,
and off (after a 20 second delay) after the arc stops.

If installed on a Mobiflex 200-M system with a
K1669-1 Lamp Kit, the Sensor will control the opera-
tion of the Mobiflex 200-M extraction fan.

If installed on a wall-mounted system including
SF2400 Fan with a K1669-2 Lamp Kit, the Sensor will
control the operation of the SF2400 Fan.

For information on installation with a Lamp Kit, refer to
the appropriate Lamp Kit manual.

For information on installation of a complete wall-
mounted system, refer to the SF2400 Fan manual.

For information on installation of a complete mobile
system, refer to the Mobiflex 200-M manual.

WARNING

WARNING

WH

BN

GN

IMS

LAMP

WH

BN

GN

BK

BK

A

D

B

C

Fig. 1