Service, Parameter table, Copper-fin ii/iie boiler, water heater and pool – Lochinvar Copper-fin II/IIE Boiler User Manual

Page 13

Advertising
background image

13

Parameter table

Table 1D_This table lists SMART SYSTEM control module parameters and where to access them

1

Service

(continued)

Menu

Sub

Item

Description

See

Page

User Access

Installer Access

Display Modify

Display Modify

A

1

User Code

15

Yes

Yes

Yes

Yes

2

Time and Date

15

Yes

Yes

Yes

Yes

3

Software Version

15

Yes

No

Yes

Yes

4

Temperature Units

15

Yes

Yes

Yes

Yes

5

SH Night Setback Offset

15

Yes

Yes

Yes

Yes

6

SH Night Setback Times

15

Yes

Yes

Yes

Yes

7

DHW Night Setback Offset

15

Yes

Yes

Yes

Yes

8

DHW Night Setback Times

15

Yes

Yes

Yes

Yes

B

1

SH User Setpoint

15

Yes

Yes

Yes

Yes

2

Minimum SH User Setpoint

15

No

No

Yes

Yes

3

Maximum SH User Setpoint

16

No

No

Yes

Yes

4

SH Offset

16

No

No

Yes

Yes

5

SH Differential

16

No

No

Yes

Yes

6

Manual Reset High Limit

16

Yes

Yes

Yes

Yes

7

Auto Reset High Limit

16

Yes

Yes

Yes

Yes

C

1

Hours Running SH

16

No

No

Yes

Yes

2

Hours Running DHW

16

No

No

Yes

Yes

3

Burner Cycles

16

No

No

Yes

Yes

4

Last 10 Lockouts

16

No

No

Yes

Yes

D

1

Reset Last 10 Lockouts

16

No

No

Yes

Yes

2

Service Mode Delay

16

No

No

Yes

Yes

3

Display Timeout

16

No

No

Yes

Yes

4

Bypass Valve Time

16

No

No

Yes

Yes

5

Freeze Protection Pump On

17

No

No

Yes

Yes

6

Freeze Protection Burner On

17

No

No

Yes

Yes

7

Freeze Protection Differential

17

No

No

Yes

Yes

E

1

Tank Setpoint

17

Yes

Yes

Yes

Yes

2

DHW Boiler Setpoint

17

Yes

Yes

Yes

Yes

3

SH/DHW Switching Time

17

No

No

Yes

Yes

4

DHW/SH Switching Time

17

No

No

Yes

Yes

5

Tank Offset

17

No

No

Yes

Yes

6

Tank Differential

17

No

No

Yes

Yes

F

1

Low Outdoor Temperature

18

No

No

Yes

Yes

2

High Outdoor Temperature

18

No

No

Yes

Yes

3

Setpoint at Low Outdoor Temperature

18

No

No

Yes

Yes

4

Setpoint at High Outdoor Temperature

18

No

No

Yes

Yes

5

Outdoor Shutdown Setpoint

18

Yes

Yes

Yes

Yes

6

Outdoor Shutdown Differential

19

Yes

Yes

Yes

Yes

7

Shfit Reset Curve

19

No

No

Yes

Yes

8

Boost Temperature

19

Yes

Yes

Yes

Yes

9

Boost Time

19

Yes

Yes

Yes

Yes

GENERAL

TEMPERATURE

SETTINGS

DA

TA

LOGGING

FUNCTIONS

DHW SETTINGS

OUTDOOR RESET

Copper-fin II/IIE Boiler, Water Heater and Pool

Service Manual

Advertising
This manual is related to the following products: