HANDLING

A pallet jack or forklift truck can be used to move the
Demo Zone and to install the caster kit. The place-
ment of the pallet jack or forks must balance the
Demo Zone load to prevent tipping.

FALLING EQUIPMENT can cause
injury.

• Do not lift the Demo Zone by over-

head crane.

• Do not lift the Demo Zone with gas

cylinder in place.

• Lift from front of Demo Zone only.

Do not lift from left, right or rear
sides.

The Demo Zone is too heavy for one person to
move by hand on an inclined surface. Avoid situa-
tions that may injure yourself or others.

A-4

INSTALLATION

DEMO ZONE

A-4

GENERAL INSTALLATION REQUIREMENTS

LOCATION

Locate the Demo Zone on a flat surface. The Demo
Zone is intended for indoor use only. The Demo Zone
must be sheltered from rain and water.

ENGINE EXHAUST

Provide an exhaust capability for the Ranger 250
machine. Flexible metal exhaust hose, available
from automobile parts stores, should be used to
exhaust gasses to the outdoors. The exhaust pipe
on the Ranger 250 is 1.5" diameter nominal. Use a
clamp at the muffler to ensure a good seal.

The exhaust pipe and flexible metal exhaust hose
is hot! Do not touch when hot. Keep flammable
material away from the exhaust hose. Place a "Hot
- Do not touch" sign near the hose to warn of the
hazard.

Ensure that there is sufficient fresh air and venti-
lation available during operation of the Ranger
250.

WELDING SMOKE AND FUME

Provide an exhaust for welding smoke and fume.

STACKING

The Demo Zone is not designed for stacking.