Warnings – Lennox Hearth C210 User Manual

Page 14

Advertising
background image

14

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

WARNINGS

The blower must be plugged directly into a properly

grounded three-prong receptacle, 120 VAC, 60 Hz, single

phase. Do not cut or remove the grounding prong from

this plug. Do not route power cord under or in front of

appliance.

Installation must be in accordance with National Elec-

trical Code, ANSI/NFPA 70 - latest edition. In Canada,

the current CSA C22-1 Canadian Electrical Code - latest

edition.

DANGER: Disconnect power before servicing blower.

BLOWER OPERATION

Figure 12 - Blower Wiring Schematic

Figure 11 - Blower Controls

Blower Operation

The blower can be operated manually or automatically (blower will

turn on when the insert is hot and turn off when the insert is cool).

The rocker switch on the control panel allows you to select between

manual operation or automatic operation as follows (see Figure 10):

MANUAL OPERATION: Turn rocker switch to the manual position (up)

and adjust rheostat knob to the desired speed. The blower will have to

be manually turned “OFF” by rotating the rheostat knob counterclock-

wise until it clicks.

AUTO OPERATION: Turn rocker switch to the “AUTO” position and

the rheostat to the ON position (rotate rheostat knob clockwise until it

clicks). When the insert warms up, the blower will automatically turn

on (adjust rheostat knob to the desired speed setting). When the insert

cools down, the blower will automatically turn off.

Rheostat Operation - The highest blower speed is obtained by turning

the rheostat knob clockwise until it clicks “ON”, then rotate towards

“HIGH” to increase blower speed. Rotate the knob clockwise for a

lower speed. To turn off, continue to rotate the knob counterclockwise

until it clicks “OFF.”

Blower Speed Control

Knob (rheostat)

Manual / Auto

Rocker Switch

ROOM AIR

BLOWER

SPEED

CONTROL/OFF

TWO POSITION

SWITCH

MANUAL/TEMPERATURE

AUTO-RESET

TEMPERATURE

SWITCH N/O

POWER CORD

RED

RED

RED

YLW

BLK

WHT

GRN

NOTE: SWITCH CONDITIONS
GIVEN AT ROOM TEMPERATURE

N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN

= FEMALE DISCONNECT
= MALE DISCONNECT
= STUD CONNECTION

ROOM AIR

BLOWER

SPEED

CONTROL/OFF

TWO POSITION

SWITCH

MANUAL/TEMPERATURE

AUTO-RESET

TEMPERATURE

SWITCH N/O

POWER CORD

RED

RED

RED

YLW

BLK

WHT

GRN

NOTE: SWITCH CONDITIONS
GIVEN AT ROOM TEMPERATURE

N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN

= FEMALE DISCONNECT
= MALE DISCONNECT
= STUD CONNECTION

Blower Operation Guidelines

While in auto operation mode, the blower will turn off and on based on

the temperature of the appliance. Auto operation ensures there is suffi-

cient heat build-up to warm the air being moved by the blower before the

blower is turned on. Likewise, when the appliance cools off, the blower

is turned off to prevent circulating cool air. Depending on the size and

intensity of the fire it may be necessary to adjust the blower speed ac-

cordingly to ensure un-interrupted blower operation. For example a small

fire may require a slower blower speed to keep the heat output by the

blower consistent. If the blower is operated in manual mode, it may be

necessary to adjust the blower speed as the fire begins to burn down and

the appliance is no longer hot enough to effectively heat the air moved

by the blower. If the air coming from the blower feels cool, one should

either decrease the blower speed or stoke the fire to build up more heat.

ROOM AIR

BLOWER

SPEED

CONTROL/OFF

TWO POSITION

SWITCH

MANUAL/TEMPERATURE

AUTO-RESET

TEMPERATURE

SWITCH N/O

POWER CORD

RED

RED

RED

YLW

BLK

WHT

GRN

NOTE: SWITCH CONDITIONS
GIVEN AT ROOM TEMPERATURE

N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN

= FEMALE DISCONNECT
= MALE DISCONNECT
= STUD CONNECTION