N o t e, Attaching wires w rh b o rc y g c, Wrh b o rc y g c – Lux Products PSD111 User Manual

Page 2: Heating systems cooling systems, Heating / cooling systems

Advertising
background image

2

© COPYRIGHT 2004 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED

N O T E

If you are mounting the base to a

soft material like plasterboard or if

you are using the old mounting

holes, the screws may not hold.

Drill a 3/16-in. (4.8mm) hole at

each screw location, and insert the

plastic anchors provided.

Then mount the base as

described below.

WIRING DIAGRAMS

These diagrams are provided for new installations or un-referenced wires.

G

C

Y

RC

O

B

RH

W

TERMINALS

BASE

TAB

5. Route the wires through the large hole in the base plate by the
terminal block. Hold the base against the wall, with the wires
coming through. Position the base for best appearance (to hide
any marks from an old thermostat). The terminal block should be
either to the right of or below the routing hole. Attach the base to
the wall with the two screws provided.

C A U T I O N

Read instructions carefully before removing any wiring from existing thermostat. Wires

must be labeled before they are removed. When removing wires from their terminals,

ignore the color of the wires since they may not comply with any standard.

REMOVING THE OLD THERMOSTAT
1. Switch electricity to the furnace and air conditioner OFF; then
proceed with the following steps.

2. Remove cover from old thermostat. Most are snap-on types and
simply pull off. Some have locking screws on the side. These must

be loosened.

3. Note the letters printed near the terminals. Attach labels (enclosed) to each wire
for identification. Label and remove wires one at a time. Make sure the wires do
not fall back inside the wall.

4. Loosen all screws on the old thermostat and remove it from the wall.

MOUNTING THE PSD111 ON THE WALL
1. Decide whether the thermostat will be mounted vertically or horizontally.

Y

W

C A U T I O N

Be careful not to drop the unit or disturb electronic parts.

2. Strip insulation 3/8 in. (9.5mm) from wire ends and
clean off any corrosion.

3. Fill wall opening with non-combustible insulation to
prevent drafts from affecting the thermostat.

4. Cup the thermostat with one hand behind the
thermostats display. Separate the unit from it’s
base plate using the tabs protruding from it’s
body with the other hand.

Y

W

Y

W

R

ATTACHING WIRES

W

RH

B
O

RC

Y

G

C

J

U

M

P
E
R

P
R
O
V

I

D
E
D

W

RH

B
O

RC

Y

G

C

J

U

M

P
E
R

P
R
O
V

I

D
E
D

W

RH

B
O

RC

Y

G

C

J

U

M

P
E
R

P
R
O
V

I

D
E
D

W

RH

B
O

RC

Y

G

C

J

U

M

P
E
R

R
E

M

O
V
E
D

W

RH

B
O

RC

Y

G

C

J

U

M

P
E
R

P
R
O
V

I

D
E
D

GAS

VALVE

TYPICAL 2 WIRE HEAT HOOKUP

24 VAC AND MILLIVOLT SYSTEMS

AC

LINE

24

VAC

XFMR

OPTIONAL

COMMON

GAS

VALVE

TYPICAL 3 WIRE HEAT HOOKUP

WHERE THIRD WIRE IS FAN WIRE

AC

LINE

24

VAC

XFMR

FAN

OPTIONAL

COMMON

GAS

VALVE

TYPICAL 4 WIRE HOOKUP

HEATING AND COOLING

AC

LINE

24

VAC

XFMR

FAN

COOL

COMPRESSOR

OPTIONAL

COMMON

GAS

VALVE

TYPICAL 5 WIRE HOOKUP

HEATING AND COOLING

AC

LINE

24

VAC

24

VAC

XFMR

AC

LINE

XFMR

FAN

COOL

COMPRESSOR

OPTIONAL

COMMON

TYPICAL SINGLE STAGE HEAT PUMP

HEATING AND COOLING

24

VAC

AC

LINE

XFMR

CHANGEOVER

VALVE

FAN

HEAT

COMPRESSOR

OPTIONAL

COMMON

NOTE: ADD JUMPER BETWEEN "W" AND "Y"

B

O

B

O

OR

USE "B" OR "O"
BUT NOT BOTH

ALL COMMON WIRES ARE OPTIONAL
AND MAY BE TAPED OFF

W

RH

B
O

RC

Y

G

C

OPTIONAL

OPTIONAL

OPTIONAL

OPTIONAL

OPTIONAL

OPTIONAL

TC B

C

F

G

RC

RH

V 5

R

H

W

4

J

U

M

P
E
R

P
R
O
V

I

D
E
D

ALL COMMON WIRES ARE OPTIONAL
AND MAY BE TAPED OFF

** IF A "B" WIRE IN YOUR SYSTEM IS A

SYSTEM COMMON, THEN CONNECTING IT
AT THE "B" TERMINAL MAY CAUSE
DAMAGE TO YOUR SYSTEM

* IF Y AND "C" ARE BOTH PRESENT,

"C" IS THE COMMON WIRE

W

RH

B
O

RC

Y

G

C

DO NOT CONNECT
A "B" WIRE HERE
UNLESS YOU ARE SURE
THAT IT IS CORRECT

B

TC

C

F

G

C*

6

Y

RC

RH

V 5

R

B**

H

W

4

O

J

U

M

P
E
R

P
R
O
V

I

D
E
D

J

U

M

P
E
R

R
E

M

O
V
E
D

ALL COMMON WIRES ARE OPTIONAL
AND MAY BE TAPED OFF

** IF A "B" WIRE IN YOUR SYSTEM IS A

SYSTEM COMMON, THEN CONNECTING IT
AT THE "B" TERMINAL MAY CAUSE
DAMAGE TO YOUR SYSTEM

* IF Y AND "C" ARE BOTH PRESENT,

"C" IS THE COMMON WIRE

* IF Y AND "C" ARE BOTH PRESENT,

"C" IS THE COMMON WIRE

B**

W

RH

B
O

RC

Y

G

C

B

TC

C

F

G

R

RC

C*

6

Y

RH

V 5

H

W

4

O

ALL COMMON WIRES ARE OPTIONAL
AND MAY BE TAPED OFF

W

RH

B
O

RC

Y

G

C

B TC

C

F

G

C*

Y

6

RC

R

V

J

U

M

P
E
R

P
R
O
V

I

D
E
D

HEATING SYSTEMS

COOLING SYSTEMS

4- or 5-WIRE WITH ONE TRANSFORMER

5- or 6-WIRE WITH TWO TRANSFORMERS

HEATING / COOLING SYSTEMS

HEATING / COOLING SYSTEMS

DO NOT CONNECT
A "B" WIRE HERE
UNLESS YOU ARE SURE
THAT IT IS CORRECT

Advertising