Lanier 480-0081 User Manual

Page 2

Advertising
background image

MATERIAL SAFETY DATA SHEET


Page 2 of CP-400

Section 6: Accidental Release Measures


Spill / leak Procedures: If spilled, sweep up using an approved toner vacuum with a 0.5 micron filter or smaller, such as the Atrix
AAA Toner Vacuum or 3M Toner Vacuum. Use of a vacuum cleaner not rated for toner particles, could result in a fire or personal
injury. Remove residue with soap and cold water.
Miscellaneous: Keep product out of sewers and watercourses.
Personal protection: Avoid inhalation of dust.

Section 7: Handling and Storage


Special Handling:


Cleanse skin after contact before breaks or meals, and end of workday.
Do not handle in areas where the wind blows.
Minimize the breathing of dust.

Special Storage:

Avoid direct sunlight. Keep out of reach of children. Store in a cool, dry place. Below 35C (95F)

Section 8: Exposure Control and Personal Protection Information:


Respiratory Protection: none required under normal use. Hand Protection: none required under normal use.

Eye Protection: none required under normal use. Skin Protection: none required under normal use.

Section 9: Physical and Chemical Properties

CHARACTERISTICS:
Appearance: Black

Melting

point:

N/a

Form: Powder

Vapor

pressure:

N/a

Odor: Slight

plastic

odor Vapor

density:

N/a

Solubility in Water:

Insoluble

Evaporation rate:

N/a

Boiling

point: N/a

Section 10: Stability and Reactivity


Conditions to avoid: none Materials to avoid: none Stability: Stable
Hazardous decomposition products: Will not occur

Section 11: Toxicological Information:


Ames test: negative

Acute skin irritation: n/a

Acute oral toxicity: 5000mg/kg (rat)

Acute allergenic effects: n/a

Special effects: Carcinogenicity: In 1996 the IARC reclassified Carbon Black as a Group 2B carcinogen (possible human
carcinogen). This evaluation is given to carbon black for which there is inadequate human evidence, but sufficient animal
evidence. The latter is based upon the development of lung tumors in rats receiving chronic inhalation exposures to free carbon
black at levels that induce particle overload of the lung. Studies performed in animal models other than rats have not
demonstrated an association between carbon black and lung tumors. Moreover, 2-years cancer bioassay using a typical toner
preparation containing carbon black did not demonstrate an association between toner exposure and tumor development in rats.

Section 12: Environmental / Ecological Information


Acute toxicity to fish: N.A.

Bioaccumulation: Not known in bioaccumulation

Persistence/Degradability: Not known

Acute toxicity to daphnia: Not available

Algae inhibition test: Not available

Section 13: Disposal Consideration


Used Toner should be disposed of under conditions that meet all federal, state and local environmental regulations. Disposal
regulations vary from locality to locality; therefore consult your local Lanier office or the EPA to determine the proper method for
disposal. Do not incinerate loose or spilled Toner.

Section 14: Transportation Information

International regulations:
RID/ADR

Not applicable

ICAO-TI/ATA-DGR Not applicable

DOT 49 CFR

Not applicable

UN Classification Number

Not applicable

ADNR

Not applicable

IMDG Code

Not applicable


Specific precautionary transport measures: Avoid direct sunlight. Do not keep over 35

°C (95°F).

Specific material to avoid:

None in normal use.


Information on this data sheet represents our current data and best opinion as to the proper use in handling of this product under
normal conditions.

On the basis of the data available to us, this product is not a dangerous substance. One should, however, observe the

usual precautionary measures for dealing with chemicals.


Advertising