Accessories, K148 nozzle installation, Operation – Lincoln Electric MAXSA IM10024 User Manual

Page 27: Loading of wire

Advertising
background image

C-5

ACCESSORIES

C-5

10. Line up the lower spot in the center guide tube (G)

with the 3/8” (9.5 mm) set screw (H) and tighten the

screw securely.

11. Replace the brass thread protecting collar (E). It is

important that this protecting collar be pulled up

against its locating shoulder, otherwise the tip lock-

ing nut will not clamp the tip securely.

12. Replace the contact tip and its clamping nut (D)

and tighten securely.

13. Assemble the proper combination of extension

guides (Items 12, 13 and 14) with locking nut (Item

11) for the welding procedure to be used.

14. For Submerged Arc welding, screw the flux hose

clamp (Item 10) onto the extension housing.

K148 Nozzle Installation

To install the nozzle on the head, insert the outgoing

wire guide from the head into the nozzle assembly.

Place the combined assembly in position on the bottom

of the wire feed roll box. Clamp it in place using the two

clamps supplied with the head.
Before pulling the clamps up tight the nozzle must be

positioned relative to the travel direction as shown in

Figure C.6. This position is set so accidental contact

between the work and the nozzle will not compress the

contact pressure spring. If positioned otherwise, such

accidental contact may cause arcing inside the contact

tip.
After the nozzle is positioned in the proper relationship

with the travel direction, the connector tab for the elec-

trode cables can be moved to any of four positions 90

degrees apart. To change the tab, remove the two 1/4-

20 hex head screws. ap the connector tab to loosen it

from the tapered collar on the nozzle body. Turn the tab

to the desired position. Replace and tighten the 1/4-20

screws.

Operation

The same contact tip, S13763, is used for 3/32” (2.4

mm) through 3/16” (4.8 mm) diameter electrodes.

S16388 is used for .062 (1.6 mm) and 5/64 (2.0 mm)

electrode.

Loading of Wire

Straighten the start end of the coil for at least eight inch-

es, pass the end down through the appropriate wire

straightener. Inch the wire through the wire feeder and

the nozzle. When using .062 (1.6 mm) or 5/64 (2.0 mm)

Innershield electrode with a K148-C nozzle, make sure

that the wire is in the “vee” groove of the pressure tang.

For the .062 (1.6 mm) and 5/64 (2.0 mm) wire sizes, it

may be necessary to back off on the idle roll pressure

so that there is little or no flattening of the wire.

Because the electrode is held against one point of the

contact tip, it wears a groove at that point. When the

groove is about one half the diameter of the electrode,

rotate the contact tip to a new position per the instruc-

tions below. Careful positioning of the contact tip will

provide four to six wear spots depending upon the elec-

trode size.

When welding with the small diameter electrodes, it will

be necessary to change contact position more frequent-

ly since the amount of tip wear that can be tolerated is

much less. The tang should never be allowed to touch

the I.D. of the contact tip. If the groove is allowed to

wear until the tang touches the I.D. of the contact tip,

welding current passes through the tang. This causes

electrical wear and overheating of the tang and the con-

tact tip. See Figure C.7.

To rotate the tip, clip the end of the electrode and inch it

up until it is free of the contact tip. Loosen the locking

nut about one-half turn and pull the nozzle body to

relieve the pressure of the tang against the inside of the

contact tip hole. At this moment rotate the tip the proper

amount and then retighten the locking nut.

MAXSA™ 22 & 29 WIRE DRIVES

Connector

Tab

Nozzle

Pivot

Contact

Pressure

Spring

Nozzle

Travel

Work

Travel

Locking

Nut

Contact

Tip

Tang

Electrode

New

Too Late

Time to

Rotate

Contact

Tip

FIGURE C.6

FIGURE C.7

Advertising