TEST MODE

✦ Even though this is a self-monitoring supervised

system, the National Burglar and Fire Alarm
Association recommends that all security
systems be tested manually on a regular basis.

1. The system must be in Off Mode before

switching to Test Mode.

2. Switch the system into Test Mode by entering a

user code and pressing TEST.

When the system is switched to the Test Mode, the

keypad(s) will sound a “Gong” and four “Beeps”.

3. Holding down the TEST button in Test Mode will

light all of the keypad’s indicators.

The sensor status indicators will fl ash for each sensor

programmed into the Control Panel.

4. Go to each sensor and press its test button or

open and close the protected opening.

5. To test the wireless keypad, press the wireless

keypad’s

key.

The keypad(s) will make a “Bing” sound as each sensor

is tested, followed by 1-3 beeps indicating signal strength
with 3 beeps being the strongest signal.

As each sensor is tested, the sensor status indicator for

the sensor will stop fl ashing and return to showing the
current status of the sensor.

6. Continue testing until there are no fl ashing

sensor status indicators.

SENSOR OPERATION IN EACH SYSTEM MODE

SENSOR FUNCTION

OFF MODE

CHIME MODE

HOME MODE

AWAY MODE

AUTOMATION

ACTIVATES AND DEACTIVATES THE AUTOMATION OUTPUT

EMERGENCY

ARMED 24-HOURS - TRIGGERS EMERGENCY ALARM

PANIC

ARMED 24-HOURS - TRIGGERS SILENT PANIC ALARM

FIRE

ARMED 24-HOURS - TRIGGERS FIRE ALARM

PERIMETER

DEACTIVATED

CHIME

INSTANT BURGLARY ALARM

EXIT/ENTRY

DEACTIVATED

CHIME

DELAYED BURGLARY ALARM

INTERIOR

DEACTIVATED

DEACTIVATED

DEACTIVATED

INSTANT BURGLARY ALARM UNLESS

ACTIVATED DURING AN ENTRY

DELAY, THEN IT IS DELAYED

CHIME

CHIME

2-BUTTON ARM/DISARM (LEFT)
2-BUTTON AUTOMATION (RIGHT)
EMERGENCY (BOTH BUTTONS)

LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE †

IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡

LEFT BUTTON SWITCHES SYSTEM TO OFF MODE ‡

2-BUTTON ARM (LEFT)
2-BUTTON DISARM (RIGHT)
EMERGENCY (BOTH BUTTONS)

LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE †

IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡

RIGHT BUTTON SWITCHES SYSTEM TO OFF MODE ‡

ENVIRONMENTAL

ARMED 24-HOURS - TRIGGERS ANNUNCIATION ONLY

INTERIOR HOME

DEACTIVATED

DEACTIVATED

INSTANT BURGLARY ALARM

NOTE: If the system is left unattended in Test

Mode, it will automatically switch back to Off Mode
after three minutes.

✦ When directly connecting (without a telephone

line) to the DUAL 824 with the RA-2400 remote
access software (Version 1.3 or later), press the
EMERGENCY key while in Test Mode to cause the
control panel to connect to the modem.

START IN OFF MODE

(OPTIONAL)

YOUR
USER
CODE

1 GONG
& 4 BEEPS

DONE

TEST MODE

SENSOR FUNCTION TABLE

CAN BE HOME MODE USING PROGRAMMING STEP 50

‡ CAN BE CHIME MODE USING PROGRAMMING STEP 51

Advertising