Lennox Hearth T300P User Manual

Page 26

Advertising
background image

SPECIFICATIONS - Model T300P Series

Page 26

Flue Size

3” / 76mm Rear


Width, Overall

28 3/4” / 730 mm


Depth, Overall

26 1/2” / 660 mm


Height

28

3/4” / 730 mm


Floor to Rear
Flue Center

8 3/4” / 222 mm


Facing Back of Unit,
Outside Edge of Left Leg
To Center of Rear
Flue Outlet

10 1/2” / 267 mm


Floor to Rear
Outside Air Inlet

10” / 254 mm


Facing Back of Unit
Outside Edge of Left Leg
To Center of Air Inlet

17 1/2” / 445 mm


Floor Protection

+ Front and Sides: 6”/152mm

Requirements

Back: Up to 6” / 152mm


Standard Features

Fastfire Self Igniter

Wall Thermostat

(wire

included)


Hopper Capacity

50 lbs.


Burn time

♦ 14-34 hours


Fuse, Control Board

5 amp, 25 volt, 3AG*

Fuse, Igniter

6 amp, 125 volt*


Heat Input (Max.)

♦ 13,000-32,000 BTU / hr


Overall Efficiency

85%


Emissions

♦ 0.43 gram / hr (varies w/

size and type of fuel)
EPA exempt


Ship Weight

363 lbs.


Room Air Blower

150 CFM; 1.5 amps,
2175 rpm


Auger Motor

1 RPM; .4 amps


Exhaust Blower

95 CFM: 1.0 amps,

2880 rpm

Note: Dimensions shown are approximations only (+/- ¼”)

BACK VIEW


SIDE VIEW

+

Non-combustible thermal rated floor protection must

be used when installed on carpet (see Floor Protec-

tion, page 5). When installed at clearances less

than 6”, the floor protector is only required to ex-

tend to the wall.

Fuel delivery and burn times will vary depending

on size and type of fuel used. Estimated heat in-

put based on fuel value of 8400 BTU per lb.

* Fuses are rated as fast blow.

Face of door
opening to
stove back

28 3/4”

10 “

10 1/2”

17 1/2”

8 3/4”

26 1/2”

28 3/4”

23”