About Switch Stacking

Appendx B

24/48-Port 10/100 + 4-Port Ggabt Reslent Clusterng Smart Swtch wth 2 Combo SFPs

before the split. Since the Backup Master was not

acting as a master prior to the split, it will initiate

a topology database and port-learning process.

Traffic might be halted for a short period of time

until synchronization (unit and port configuration)

is completed. New units learned by the Backup

Master will notify the system administrator (using

SYSLOG messages and SNMP traps).
In either case (steps b and c above), the subgroup

will continue to work as it did before the split,

except that the number of units is lower than prior

to the split.
No unit ID changes are made in either subgroup.
Each new stack will have a Master (one has the

original Master, the other has the Backup). They

thus operate as two separate stacks, both having

the same configuration and hence the same IP

address.

WARNING:

Both resulting stacks will have the

same IP Address. This may lead to problems on

the network, since there would be no way for

users to connect to one of the stacks through

its IP address.

Subgroup Contains Neither Master Unit nor Backup Master
Unit

Please note that this is exactly the same as the case of a

failed master, where no backup is available.

In this case the units with ID 3-6 (3-4 for SLM248G4S) in

this subgroup will not renumber themselves, and will

remain shut down until a stack Master enabled unit is

connected, and starts to operate as stack master. It is

the responsibility of the Master-discovery process to

see that the master is gone.
In this subgroup, the units lose connection with the

Master. Since they started as a running stack and none

of them are in factory default mode, renumbering will

not take place, and even a Reset of the units will not

affect unit ID assignment (As noted above, units can

be renumbered only by a stack Master).
No unit ID changes are made in either subgroup.

Again it should be emphasized that none of the units in

either half of the stack will renumber themselves.

Merging Two Stacks

In this example, the user would like to merge two working

stacks and create one stack out of those two stacks. In this

example one should distinguish between two scenarios:

d.

e.
f.

The incoming units are turned off before insertion and

then powered back up afterward
The two stacks are kept running during the insertion

(for example, the stacking cables of the two stacks are

connected)

Incoming Units Turned Off Before Insertion, then Turned On
After Insertion

This is exactly the same as inserting units into a running

stack (refer to “Replacing a Failed Stack Member in a

Running Stack”). The only difference is that more than

one unit will be inserted into the stack and therefore for

each unit inserted to the stack the same process will be

executed.

Both Stacks Kept Running During Insertion

If each of the joined stacks has a Master unit, both Master

units will perform Master discovery and participate in a

Master Election, as described above. One of the Master

units will be selected as the Master unit—for the merged

stack. The criteria for choosing the master are:

Force Master
System Up Time
Lowest Unit ID
Lowest MAC

The process of master selection between the two master

units is as follows:

If force master is enabled then the unit which is forced

is chosen.
Up time is measured by quantities of periods of 10

minutes. If the number of 10 minute periods is higher

for one of the units then this unit is chosen.
If both units have the same up time (measured in

periods of 10 minutes) the unit with the lowest unit

ID is elected.
If both Master unit IDs are equal the unit with the

Lower MAC is chosen.
The Master unit that loses its “mastership” in the Master

election process will be renumbered if the unit ID was

dynamically allocated. renumbering will now allocate

it a new number by the new Master, as a stack member,

or possibly Backup Master. It should be emphasized

that in no case will there be two units with the same

Unit ID at the end of this process.
The Master unit that loses its mastership in the Master

election process will be shut down if the unit ID was

manually allocated. It is recommended that the

administrator configure it to auto-assigned Unit ID

before reconnecting it to the stack.