Operation – Lincoln Electric 205-TAC/DCTIG User Manual

Page 20

Advertising
background image

B-5

OPERATION

B-5

4. Release the TIG torch trigger.

The output current of the machine will turn OFF and
the gas valve will remain open to continue the flow
of the shielding gas. The duration of this postflow
time is adjusted by the Postflow parameter. This
operation is shown in (4 step diagram 1).

Possible variations of this standard sequence are
shown in (4 step diagram 2). By releasing and re-
pressing the TIG torch trigger during the downslope
step, the output will immediately drop to and hold at
the Finish Current. Releasing the trigger will turn off
the output and begin postflow. This operation shown
in (4 step diagram 2).

9. Welding selection button - Permits selection of the welding

mode. The LED beside the symbol confirm the selection:

• Stick Crisp-used for E6010 and other cellulosic electrodes
• Stick Soft-used for low Hydrogen and E7018 electrodes
• TIG DC
• TIG AC (AC/DC model only)

10. Electrode Connection (Negative) - For quick disconnect

system using Twist-Mate

TM

cable plugs with gas pass

through for TIG Torches.

11. Remote Control Connector - For the connection of a

Lincoln Foot Amptrol, Hand Amptrol or Arc Start Switch.
See the ACCESSORIES section for available options.

12. Electrode Connection (Positive) - For quick disconnect

system using Twist-Mate

TM

cable plugs

13. Welding Parameter Display - LEDʼs show which mode or

welding parameter is activated for adjustment.

• If it is necessary to modify the welding parameters "Item

13":

- Wait four seconds after the LEDʼs on the panel have

gone out, the welding current LED will be lit.

- Press the SETUP/Parameter push button "Item 4";

every time the push button is pressed, one of the
LEDʼs in the diagram “Item 13” comes on (in clock-
wise sequence) and the value of the parameter
appears on the Digital display "Item 6". Stop at the
desired parameter.

- Rotate the Output/Parameter Adjust Knob"Item 5"

and modify the parameter value.

- Press the SETUP/Parameter "Item 4" push button

again to pass to another parameter, or wait five sec-
onds and the Weld Current LED will come on again.

14. VRD (Voltage Reduction Device) Status Lights- Voltage

reduction device can be enabled from the set-up menu and
an output voltage limit can be set that reduces the output
open circuit voltage when not welding to that limit. If enabled
when the machine is sitting idle the Green VRD on light will
illuminate to indicate the voltage is reduced below the set
limit. If the VRD device is not enabled (factory default) from
the set up menu or while welding the red VRD off light will
illuminate.

Note: The green VRD on light will illuminate in TIG mode until

the output is triggered even when VRD is disabled.

V205-T DC & V205-T AC/DC TIG

4 STEP DIAGRAM 1

4 STEP DIAGRAM 2

WELDING PARAMETER DEFAULTS AND RANGES

PARAMETER

VALUE

MIN

MAX

DEFAULT

START CURRENT

AMPS

6

MAX

6

UPSLOPE

SEC.

0

10

0.2

WELD CURRENT*

AMPS

6

MAX

100

DOWNSLOPE

SEC.

0

10

1.0

FINISH CURRENT

AMPS

6

MAX

8

POSTFLOW

SEC.

0.2

60

5.0

PULSE FREQUENCY

HZ

0.1

500

0.5

% ON TIME

%

5

95

50

BACKGROUND CURRENT

% OF WELD CURRENT

1

100

20

AC FREQUENCY (AC/DC model only)

HZ

20

150

100

AC BALANCE

% EN

35

85

75

(AC/DC model only)

(EN = Electrode Negative)

MODE

DC TIG

TRIGGER

2 STEP

LOCAL / REMOTE

LOCAL

(1)

(2)

(3)

(4)

*

Maximum Weld Current can be limited by input voltage, Welding Mode, AC TIG waveform and AC TIG frequency.