NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

i

nstallation

P

roCeDure

- f

aCtory

-B

uilt

Z

ero

C

learanCe

f

irePlaCes

Fireplace and Chimney Requirements

The Performer™ C/A210 insert must only be installed in

a zero clearance factory-built fireplace using 6” (152mm)

stainless steel pipe extending from the insert’s flue into the

chimney of the fireplace. For optimum safety and perfor-

mance we recommend

a full length stainless steel liner directly connected to the

insert’s flue outlet.

The Performer™ C/A210 insert must only be installed in

a zero clearance factory-built firplace that is structurally

sound. Fireboxes

or chimneys that have flaws, burnouts, or warping must be

replaced or repaired prior to installation. Check with your

fireplace manufacturer if any problems exist.

All convection vents and louvers must be left unmodified

and unobstructed.

The Performer™ C/A210 insert can only be installed in the

following brands of factory-built zero clearance fireplaces:

SUPERIOR, HEATILATOR, MAJESTIC, MARTIN, PREWAY,
MARCO, TEMCO, and FMI.

The firplace cavity must be 36” (914mm) in width, 21”

(533mm) in height, and 14” (356mm) in depth. Installation

in larger size fireboxes of the same brands is permissible.

Installations into other brands of the same size is permissible
only with approval from local building officials.

Modifications allowed to the factory-built fireplace are as

follows:

- Remove the damper

- Remove the smoke shelf or smoke baffle

- Remove ember catches

- Remove viewing screen/curtain

- Remove side and rear bricks

- Remove the fire grate

- Remove doors

Clearance to Combustibles

See “Required Clearances” on page 7.

Fireplace Pre-Installation Preparation

NOTE: LENNOX HEARTH PRODUCTS RECOMMENDS PRO-

FESSIONAL INSTALLATION BY A LICENSED AND BONDED

INSTALLER. SEE YOUR DEALER FOR RECOMMENDATIONS.

IMPROPER INSTALLATION OR MIS-USE WILL VOID YOUR

WARRANTY AND CREATE A SERIOUS SAFETY HAZARD.

Remove any doors or screen materials from the fireplace

opening. Remove the damper mechanism completely. Also

remove grates or ember catches inside the fireplace hearth.

If your fireplace is equipped with a smoke shelf or baffle and

if it interfers with the installation it may be removed. Side

and rear refractory may also be removed, if necessary, to

facilitate installation. No modifications shall be done unless

allowed on the previous list. Retain all removed parts, they

must be reinstalled before the fireplace can be used in it’s
original condition.

Insert Pre-Installation Preparation

Install the two 3” (76mm) long bolts (with the head up)

through the nuts attached to the insert on the lower rear

corner of each side. This will allow you to level the insert

when placed into the fireplace.

Measure from the front of the top surround

mount to the

center of the flue. Determine if there is an alignment problem

in connecting a liner from the chimney to the insert’s flue.

If there is an alignment problem, connection can be made

using a short piece of stainless flex or a stainless steel offset

box (available from your dealer). Before installing the liner,

make any attachment brackets or drill any holes in the liner,

offset box, or insert. Once installed, it may be difficult or

impossible to drill additional holes.