Step 1: Selecting Speaker Location

One CNXQ™ Flat Panel Ceiling Speaker is designed
for rooms smaller than 1200 sq. ft. and with a ceiling
height of 9–12 feet.

Before starting the system installation, speaker placement
needs to be determined. This speaker is designed to
be mounted in the ceiling in or near the middle of the
classroom (See figure 1.). The speaker lays directly into the
acoustic ceiling grid, so locate the tile that is approximately
in the center of the classroom.

Step 2: Installing and Connecting the Speaker Wire

A. Identify a suitable location for the receiver/amplifier

where it is easily assessable, close to a power outlet,

and at least 6 feet away from any computers.

B. Remove the ceiling tile from the ceiling that was

identified in Step 1.

C. Set the ceiling tile on a flat work surface with patterned

side facing down. The dimensions of the CNXQ Speaker

are 2’ x 2’ Using a straight edge, cut 24” off the

end of a standard 2’ x 4’ ceiling tile as shown in Figure

2. (If the ceiling tile grid is 2’ x 2’, simply remove the

tile and replace with the CNXQ speaker).

D. Locate the coil of speaker wire. To connect the wire to

the speaker, press down on the colored terminals on

the back of the speaker, insert the wire and release

the tab to clamp it in place. Insert the black wire into

the black-tabbed terminal and the red wire into the

red-tabbed terminal.

E. Place the other end of the wire up through the opening

in the ceiling and route over the ceiling tiles and back

down the wall to the receiver/amplifier. (NOTE: when

routing wire overhead, it is important to always follow

local building and electrical codes, securing wire as

required). Do not connect the wires to the receiver

amplifier yet.

F.

If installing the speaker into a 2’ x 4’ suspended

ceiling, snap the included cross tee into the suspended

ceiling grid. Locate the slots in the grid at the center of

the 2’ x 4’ area. Insert one end of the tee, then the

other so it locks into place.

G. The speaker has an earthquake strap connected to the

back so it can be tied off to the ceiling structure for

safety purposes. Unscrew one end of the wire from the

back of the speaker to be tied off to the ceiling

supports. If local building codes do not require the use

of an earthquake strap and it is not being used, you

should completely remove the strap from the speaker

so that does not create unwanted vibration.

H. Lay the CNXQ directly onto the ceiling tile grid as

shown in Figure 3. Secure the speaker to the ceiling

with the earthquake strap as required by local building

codes. Speaker wire should also be secured to the

ceiling. DO NOT lay the speaker wire across the back

of the speaker to avoid unwanted vibration.

I.

Insert the cut tile back into the ceiling.

LightSPEED

CNXQ™ Flat-Panel Ceiling Speaker Installation

Instructions for the 820/850/880iR Receiver/Amplifier

Start your system installation with the

“System Installation” section of the User Manual

All LightSPEED speakers should be in

accordance with Uniform Building Code, state

and local building department requirements

Room Installation: Top View

CNXQ

Figure 1:

Cutting a 2’ x 4’ Ceiling Tile

Throw

Away

Remaining

Ceiling Tile

Installing the Speaker

Ceiling Tile Grid

CNXQ Speaker

Cross Tee

Ceiling Tile

Figure 2:

Figure 3:

24”

Cut with Straight Edge