Specifications, Main function, Print function – Lathem 5000E User Manual

Page 23: Other specifications, Option

Advertising
background image

Calendar

Clock accuracy

Display

Daylight saving time

Preprogramed
comments

Customized
comments

DIP switch

Memory Backup

SPECIFICATIONS

MAIN FUNCTION

Print method

Print position/
direction

Hour & minute
format

Multiple copies

Ribbon cassette

Impact Dot Matrix - 9pins
4-way Card activated
automatic, manual, semi-
automatic or combination

Adjustable trigger trip
Right/Left print by DIP
switch

12 or 24-hours format,
regular minute, 1/10, 1/100
or 5/100 of a hour

Original + 4
(Maximum thickness 3mm
or less)

Carry-on cassette type
fabric ink ribbon

PRINT FUNCTION

Year up to 2099
(Automatically adjusted to leap year)

Monthly accuracy

±

15 seconds

(at ordinary temperatures)

Digital LCD with 7 segments
Date, Hour, Minute and day
of the week indication

Auto

Selectable 7 different kinds

Available up to 3 lines

16 poles

3 year memory backup by
lithium battery.

Power supply

Power consumption
110/120VAC
..............
...............
...............
220-240/230VAC.......
..............
..............

Temperature

Humidity

Dimensions

Weight

OTHER SPECIFICATIONS

Ribbon cassette

Battery

VIS6002

VIS6001

Available of 200 prints or 72
hours during no electricity.

OPTION

110 VAC, 120 VAC
230 VAC, 220-240 VAC

20 VA max.while printing
4 VA while idling
0.2 A max.while printing
20 VA max.while printing
4 VA while idling
0.1 A max.while printing

Operating -5˚C – 45˚C

Operating 20% – 80% RH
(No condensation)

6 27/32" x 6 3/16" x 8 3/16"
(174mm(W) x157mm(D) x208mm(H))

Approximately 5.5lb.(2.5 Kg)

In case of power failure
Even if a power failure has occurred, the optional
built-in battery backs up to 72 hours (roughly three
days), provided that the battery cells are fully
charged.

No printing battery capacity
The display is flashing when detecting the low
battery capacity. Please stop printing until AC
power supply is resumed.

If you still keep printing, the time recorder will
hang up. When hung up, you have to press the
RESET switch on the control panel by using a pair
of tweezers. In this case, the calendar clock is
cleared.

1

21

Bescheinigung des Herstellers/Importeurs

Dies Gerät entspricht den Bedingungen der Niederspannungs-Vorschrift 73/23/EEC und
dem EMVG nach 89/336/EEC.

This unit complies with the Low Voltage Directive 73/23/EEC and the EMC Directive
89/336/EEC.

Maschinenlärminformationsverordnung 3. GSGV,18.01.1991:Der arbeitsplatzbezogene
Schalldruckpegel beträgt 70 dB(A) oder weniger gemäß ISO 7779.

Die zugeho¨rige Steckdose muß nahe beim Gerät angebracht und leicht zugänglich sein.