Warnings, Cautions – Lennox Hearth ELITE 875022M User Manual

Page 16

Advertising
background image

16

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

WARNINGS

Air shutter adjustment should

only be performed by a quali-

fied professional service tech-

nician.

Ensure front glass panel are

in place and sealed during

adjustment.

CAUTIONS

Soot will be produced if the

air shutter is closed too much.

Any damage due to sooting,

resulting from improperly

setting the air shutter, is not

covered under the warranty.

The air shutter door and

nearby appliance surfaces

are hot. Exercise caution to

avoid injury while adjusting

flame appearance.

1. Refer to Figure 9 for proper flame ap-

pearance. To adjust the flame, rotate the

adjustment rod toward the back or toward

the front of the fireplace (rod located in

the lower control area). Position the air

shutter to the factory setting as shown in

the table in Figure 10.

2. Light appliance (follow lighting procedure

on lighting label in control compartment

or see the Care and Operation Manual).

3. Allow the burner to operate for at least 15

minutes while observing the flame con-

tinuously to ensure that the proper flame

appearance has been achieved. If the

following conditions are present, adjust

accordingly.

• If flame appears weak or sooty, adjust

the air shutter, incrementally, to a

more open position until the proper

flame appearance is achieved.

• If flame remains blue, adjust the air

shutter, incrementally, to a more

closed position until the proper flame

appearance is achieved.

4. Leave the control knob (off/pilot/on)

in the ON position and the burner OFF/

ON switch OFF (and remote switches, if

applicable).

5. When satisfied that the burner flame ap-

pearance is normal, re-install the lower

control compartment door then proceed

to finish the installation.

MILLIVOLT
Thermocouple

Hood Igniter Rod

3/8" Min

(9 mm)

Thermopile

Pilot

Nozzels

Millivolt Appliance Checkout

The pilot flame should be steady, not lifting

or floating. Flame should be blue in color with

traces of orange at the outer edge.

The top 3/8" (10 mm) at the pilot generator

(thermopile) and the top 1/8" minimum (tip)

of the quick drop out thermocouple should be

engulfed in the pilot flame.

The flame should project 1" (25 mm) beyond the

hood at all three ports (see Figure 11 ). Replace

logs if removed for pilot inspection.

To light the burner; turn “ON” the remote wall

switch and rotate the gas valve control knob

counterclockwise to the “ON” position (“ON”

will be at the top side of the valve).

Electronic Appliance Checkout

To light the burner, turn ‘ON’ the unit mounted

On/Off switch or the optional remote wall switch.

Ensure the igniter lights the pilot. The pilot

flame should engulf the flame rod as shown

in Figure 12.

Figure 11

ELECTRONIC

Proper Flame

Adjustment

Pilot

Nozzle

3/8 To 1/2 Inch

(9 mm to 13 mm)

Ground

Electrode

Flame Rod

Hot Surface

Igniter

Figure 12

BURNER FLAME ADjUSTMENTS

Adjustment Rod Positions (when viewed from above)

Figure 10

R

E

N

R

U

B

N

I

A

M

G

N

I

T

T

E

S

R

E

T

T

U

H

S

Y

R

O

T

C

A

F

s

l

e

d

o

M

s

a

G

l

a

r

u

t

a

N

s

e

h

c

n

i

)

m

m

(

s

a

G

e

n

a

p

o

r

P

s

e

h

c

n

i

)

m

m

(

T

S

V

D

E

F

P

V

D

E

R

C

V

D

E

L

C

V

D

E

"

4

/

1

)

5

3

.

6

(

"

8

/

5

)

8

8

.

5

1

(

Air Shutter

Adjusting

Rod

Orifice

Increase Shutter

Opening In This

Direction

Decrease Shutter

Opening In This

Direction

Note - Burners are omitted in this view for clarity.

Advertising