HE Series

C

LASS

I D

IVISION

2 E

MERGENCY

L

IGHTING

Page 1 of 2

Job Information

Type:

Job Name:

Cat. No.:

Notes:

Features

Illumination: Illumination

is accomplished with lamp

heads mounted on the top of

the unit. The Class I, Div. 2

rated “H” Series lamp head

is available in a variety of

wattages, and is constructed of

gray polycarbonate to match

the housing.

Housing: Constructed of

impact-resistant, fiberglass-

reinforced polyester. Housing

color is gray and includes

stainless steel hardware. The

HE Series is UL listed for

Class I, Division 2, Groups

A, B, C & D; Class I, Zone

2, Groups IIA, IIB (+ H

2

) &

IIC; and Class II, Division 2,

Groups F & G. View-through

window allows easy monitoring

of the optional voltmeter and

ammeter. Available with Class

I, Div. 2 rated polycarbonate

sealed beam Par 36 tungsten or

halogen lamp heads.

Operating Temperature

Range: Standard location

65°F (19°C) to 85°F (30°C)

Electrical Specifications:

Lead Calcium

6 VDC 25 & 50 W:

0.18 A (120), 0.08 A (277)

12 VDC 25, 50, 100 & 125 W:

0.40 A (120), 0.18 A (277)

NiCad

6 & 12 VDC 25 W:

0.088 A (120), 0.042 A (277)

6 VDC 50 & 75 W, 12 VDC

50 W:

0.19 A (120), 0.084 A (277)

12 VDC 75 & 100 W:

0.29 A (120), 0.14 A (277)

12 VDC 125 & 150 W:

0.39 A (120), 0.18 A (277)

Diagnostic Electronics

(standard): 120/277 VAC

dual voltage input with surge

protection is standard on all

models. Charging system is

microprocessor driven with

software embedded diagnostic

routine and precision

temperature compensation.

Surge protection, brownout,

AC lockout, and low voltage

disconnect features are

standard.

Self-Testing Diagnostics

(optional): The diagnostic/

charging platform with self-

testing mode automatically

runs a one-minute self-test

every 30 days and a 30-minute

test on the sixth and twelfth

month. A one-minute or

90-minute test may be initiated

via the push to test switch on

the unit or by activating the

appropriate test command on

the optional IR test device.

Code Compliance

UL 924 and 844 listed. NFPA

101, NEC, BOCA, OSHA and

IBC illumination standards.

Temperature Rating (T-Rating)

160° (T3C). Class I, Zone 2

T-Rating 200° (T3).

Warranty

Three year full electronics

warranty. One year full plus

four year prorated lead calcium

battery warranty. Five year full

plus five year prorated nickel

cadmium battery warranty.

13.2"

(33.5 cm)

15.2"

(38.6 cm)

HE125L2HH8SD2

7.1"

(18.0 cm)

21.4"

(54.4 cm)

Advertising