TROUBLESHOOTING

CLASSIC 300G

E-4

ELECTRONIC IDLER CONTROL TROUBLESHOOTING GUIDE

Engine Will Not Return to Low

Idle in Approximately 10 Seconds

After Welding and Auxiliary Loads are Removed

Set Idler Control Switch

to the Auto Position

Check for Continuity through Idler

Control Switch

Open

Closed

Remove Molex connector

Replace Idler

from current sensing board.

Control Switch.

Operation Same

Machine Idlers

Check wiring between TBI controller and current sensing board.

1. Check for current in wires looping through

current sensor.

2. Replace current sensor.

Have TBI controller inspected at authorized service shop.

Not O.K.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.