Alter concept sr t5, Performance, Coefficients of utilization – Lightolier Alter Concept SR T5 User Manual

Page 2: Distribution candlepower curve 228, Candlepower, Distribution candlepower curve 328, Lightolier, Canlyte

Advertising
background image

Alter Concept SR T5

Page 2 of 2

2' x 4' semi-recessed direct/indirect fluorescent

Job Information

Type:

Lightolier is a Philips group brand

Lightolier

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

© 2008 Philips Group • QCH2x4PFOS.pdf

Canlyte

www.canlyte.com

3015 Louis-Amos, Lachine, Québec H8T 1C4 • (514) 636-0670 • (514) 636-0460

ZONE

DEG

ALONG 22.5

45

67.5

ACROSS

0

1172

1172

1172

1172

1172

5

1171

1171

1172

1168

1162

10

1152

1161

1160

1153

1156

15

1125

1137

1139

1138

1137

20

1095

1102

1105

1117

1116

25

1050

1056

1066

1081

1094

30

991

1007

1028

1045

1061

35

929

941

976

1000

1008

40

851

870

918

953

967

45

765

801

845

887

906

50

671

709

776

834

856

55

581

628

695

784

812

60

478

537

632

706

718

65

379

446

555

593

599

70

286

359

450

478

495

75

193

274

333

354

358

80

116

182

198

174

161

85

44

64

43

55

71

90

0

0

7

16

21

COEFFICIENTS OF UTILIZATION

ZONAL CAvITY METHOD * EFFECTIvE FLOOR CAvITY REFLECTANCE = .20

80

70

50

Wall Reflectance

70 50 30 10 70 50

30 10 50 30

10

0 .85 .85 .85 .85 .83 .83 .83 .83 .79 .79

.79

1 .78 .75 .72 .69 .76 .73 .70 .68 .70 .68

.66

2 .71 .65 .60 .56 .69 .64 .59 .55 .61 .57

.54

3 .65 .57 .51 .47 .63 .56 .51 .46 .54 .49

.46

4 .59 .51 .44 .40 .58 .50 .44 .39 .48 .43

.39

5 .54 .45 .38 .33 .52 .44 .37 .33 .42 .37

.33

6 .49 .40 .33 .29 .48 .39 .33 .28 .38 .32

.28

7 .45 .36 .29 .25 .44 .35 .29 .25 .34 .28

.24

8 .42 .32 .26 .21 .41 .31 .25 .21 .30 .25

.21

9 .39 .29 .22 .18 .37 .28 .22 .18 .27 .22

.18

10 .36 .26 .20 .16 .35 .26 .20 .16 .25 .20

.16

DETERMINED IN ACCORDANCE WITH CuRRENT IES PuBLISHED PROCEDuRES

LuMINAIRE INPuT WATTS = 67.5

Room Cavity Ratio

ZONE

LUMENS

% LAMP

% LUMINAIRE

0-30

925

17.80

24.92

0-40

1533

29.49

41.28

0-60

2807

53.98

75.57

0-90

3714

71.43

100.00

40-90

2181

41.94

58.72

60-90

907

17.45

24.43

90-180

0

.00

.00

0-180

3714

71.43

100.00

DISTRIBUTION

CANDLEPOWER CURVE 228

Performance

CANDLEPOWER

REPORT NO: LSCD079
CAT. NO: QCH2GPFOS228

2 28W T5 Fluorescent Lamps at 2600 lumens.

Efficiency: 71.4%

Candela at Nadir: 1172cd

90°

90°

180°

400

800

1200

ZONE

DEG

ALONG 22.5

45

67.5

ACROSS

0

1925

1925

1925

1925

1925

5

1921

1921

1920

1917

1917

10

1897

1903

1906

1902

1896

15

1848

1872

1868

1876

1875

20

1790

1808

1817

1831

1839

25

1723

1737

1752

1774

1790

30

1623

1649

1689

1716

1729

35

1514

1548

1594

1641

1658

40

1386

1426

1503

1560

1588

45

1247

1298

1387

1463

1494

50

1096

1156

1267

1358

1391

55

920

1003

1145

1249

1281

60

752

864

1011

1099

1131

65

592

709

864

953

971

70

439

570

702

779

802

75

300

431

528

594

601

80

177

275

336

323

304

85

68

101

76

102

110

90

0

0

15

33

38

COEFFICIENTS OF UTILIZATION

ZONAL CAvITY METHOD * EFFECTIvE FLOOR CAvITY REFLECTANCE = .20

80

70

50

Wall Reflectance

70 50 30 10 70 50

30 10 50 30

10

0 .92 .92 .92 .92 .90 .90 .90 .90 .86 .86 .86

1 .84 .81 .78 .75 .82 .79 .76 .73 .76 .73 .71

2 .77 .71 .65 .61 .75 .69 .64 .60 .66 .62 .59

3 .70 .62 .56 .51 .68 .61 .55 .51 .59 .54 .50

4 .64 .55 .48 .43 .63 .54 .48 .43 .52 .46 .42

5 .59 .48 .41 .36 .57 .48 .41 .36 .46 .40 .36

6 .54 .43 .36 .31 .52 .42 .36 .31 .41 .35 .31

7 .49 .39 .32 .27 .48 .38 .32 .27 .37 .31 .27

8 .45 .35 .28 .23 .44 .34 .28 .23 .33 .27 .23

9 .42 .31 .25 .20 .41 .31 .24 .20 .30 .24 .20

10 .39 .28 .22 .18 .38 .28 .22 .18 .27 .21 .18

DETERMINED IN ACCORDANCE WITH CuRRENT IES PuBLISHED PROCEDuRES

LuMINAIRE INPuT WATTS = 99.4

Room Cavity Ratio

ZONE

LUMENS

% LAMP

% LUMINAIRE

0-30

1520

19.49

25.16

0-40

2515

32.25

41.62

0-60

4581

58.74

75.82

0-90

6042

77.47

100.00

40-90

3527

45.22

58.38

60-90

1461

18.73

24.18

90-180

0

.00

.00

0-180

6042

77.47

100.00

DISTRIBUTION

CANDLEPOWER CURVE 328

Performance

CANDLEPOWER

REPORT NO: LSCD078
CAT. NO: QCH2GPFOP328

3 28W T5 Fluorescent Lamps at 2600 lumens.

Efficiency: 77.5%

Candela at Nadir: 1925cd

90°

90°

180°

800

1600

2400