RECOMMENDED TOOLS FOR
INSTALLATION OR SERVICE:

absorbent towels

alcohol wipe

3 mm allen wrench (G3503 only)

socket wrench

4 inch long minimum socket extension

1/4, 5/16, and 3/8 hex standard depth sockets

5/32 allen socket

medium blade slotted screwdriver

large blade slotted screwdriver, 8 inches long

minimum

two 7/16 open or box end wrenches

one 7/8 open or box end wrench

needlenose pliers

two 10 inch long adjustable wrenches

wire cutter

molex pin removal tools

tape measure

small mechanic

s mirror

flashlight

dental pick

digital multimeter (DMM)

G3503-[ ] INSTALLATION OR SER-

VICE TOOL USAGE

Fastener Usage

Qty.

Tool

Shroud to cooler base

4

all use 5/16 hex screw and 3/8 hex

Quick Disconnect (QD) bracket

2

nut. Relay may require large blade

Heat exchanger to cooler base

2

slotted screwdriver 8 in. long min.

Relay to cooler base

2

Screw to

4

3 mm allen wrench (G3503 only)

fasten reservoir to cooler base

5/16 Hex Socket (G3503-1 only)

Hose Clamp

10

1/4 hex or medium slotted screwdriver

Fan set screw

1

5/32 allen socket with wrench and 4
in. min. extension

Pump carbonator clamp screw

1

5/16 hex socket with ratchet wrench

Motor mounting bolts

4

two 7/16 open or box end wrenches

Motor access door

2

1/4 hex socket with wrench

Motor harness ground at motor

1

1/4 hex socket with wrench

terminals

2

needlenose pliers

relay terminals 1 and 2

2

large blade slotted screwdriver 8 in.
minimum long.

relay terminals 3 and 4

2

medium slotted screwdriver

All plumbing components

N/R

two 10 inch adjustable wrenches

S24505 WATER COOLER UPGRADE KIT
CONTENTS:

1 Cooler assembly, G3503-[ ]

Empty Weight: 36 lbs.

Overall Size: 22.38x14.00x12.50, LxWxH

Electrical Input: 230VAC, 2.8A max. steady state

Coolant Connections:

Welding Industry Standard Quick-Disconnect
(QD) female fittings. Top: Coolant In,
Bottom: Coolant Out

1 Cooler access panel, L9387-2
1

P4

Electrical power harness (long), S14165-467

1

P3

Electrical extension harness (short), S14165-466

1 Circuit breaker, T12287-14, spare replacement
2 fasteners, S9225-8, (1/4-20 thread, spares for

cooler mounting)

4 fasteners, S8025-91, (spares for cooler access

panel mounting)

2 Hole plugs, T10397-11
1 Ground Decal, T13260-4
8 cable ties, T13770-2
1 Electrical sleeving, E1159/B-1.00-7.00
1

B

Stencil, S21212

1 Power Wave machine label: S24503-1

2 Mounting Brackets, S10040-93
2 Fasteners, T9447-42, (#10-24 UNC-3A)
2 Plain washers, S9262-77 (Socket head- cap

screws)

RECOMMENDED COOLANTS

1. The following coolants have been determined to be

compatible with the wetted materials used in the
G3503-[ ] cooler assembly:

Distilled or deionized water

Potable tap water

Sediment-free mixtures containing a maxi-

mum of 50% ethylene glycol or automotive-
grade antifreeze and the balance of distilled
or deionized water.

2. Ethylene glycol mixtures should be selected if the

cooler may be exposed to a temperature below the
freezing point of water.

3. Consult gun, torch, and wire feeder manuals for

coolant recommendations and select one from the
above list.

4. Pure solutions and mixtures of, or materials (i.e.

towels) wetted with ethylene glycol are toxic to
humans and animals. They must not be haphaz-
ardly discarded, especially by pouring liquids down
the drain. Contact the local EPA office for responsi-
ble disposal methods or for recycling information.

5. The cooler

s reservoir has a nominal liquid capacity

of 1.6 gallons.

G3503-[ ] POWER WAVE 450 WATER COOLER UPGRADE KIT

Advertising