1101

Page 2 of 3

6 ¾" Aperture Vertical Open, Performance Series, Reflector Trim

Job Information

Type:

Zonal Lumens And Percentages

Zone Lumens %Lamp %Fixt

0-30 1043.18 32.6

49.1

0-40 1579.97 49.4

74.3

0-60 2119.92 66.2

99.7

0-90 2125.77 66.4

100

90-120

0

0

0

90-130

0

0

0

90-150

0

0

90-180 2125.77 66.4

100

** Efficiency = 66.4% **

Zonal Lumens And Percentages

Zone Lumens %Lamp %Fixt

0-30 590.62 26.8

40.7

0-40 962.92 43.8

66.4

0-60 1441.31 65.5

99.3

0-90 1450.77 65.9

100

90-120

0

0

0

90-130

0

0

0

90-150

0

0

90-180 1450.77 65.9

100

** Efficiency = 65.9 % **

Zonal Lumens And Percentages

Zone Lumens %Lamp %Fixt

0-30 530.36

31

47.5

0-40 842.82

49.3

75.4

0-60 1115.14 65.2

99.8

0-90 1117.5

65.4

100

90-120

120

0

0

90-130

0

0

0

90-150

0

0

90-180 1117.5

65.4

100

** Efficiency = 65.4 % **

Zonal Lumen Summary

Zone

Lumens

0-10

143.51

10-20

379.14

20-30

520.52

30-40

536.79

40-50

411.63

50-60

128.32

60-70

4.54

70-80

1.31

80-90

0

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

Zonal Lumen Summary

Zone

Lumens

0-10

68. 98

10-20

200.27

20-30

321.37

30-40

372.3

40-50

313.27

50-60

165.12

60-70

8.4

70-80

1.05

80-90

0

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

Zonal Lumen Summary

Zone

Lumens

0-10

63.18

10-20

181.85

20-30

285.32

30-40

312.46

40-50

214.19

50-60

58.13

60-70

1.96

70-80

.39

80-90

0

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

42W G.E. 4 PIN TRIPLE BIAX, LUMEN RATING = 3200 LMS, CL FINISH TRIM

Coefficients Of Utilization

Ceiling

80%

70%

50%

30%

0

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room Cavity Ratio

0 79 79 79 79 77 77 74 74 71 71 66

1 75 73 71 69 71 68 69 66 66 64 61

2 70 67 63 61 65 60 63 59 61 57 55

3 66 61 57 54 60 53 58 53 56 52 50

4 62 56 51 48 55 48 53 47 52 47 45

5 58 51 47 43 51 43 49 43 48 42 41

6 54 47 43 39 47 39 46 39 41 38 37

7 51 44 39 36 43 36 42 35 41 35 34

8 48 40 36 33 40 33 39 32 38 32 31

9 45 38 33 30 37 30 37 30 36 30 29

10 42 35 31 28 35 28 34 28 34 27 26

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 44

Coefficients Of Utilization

Ceiling

80%

70%

50%

30%

0

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room Cavity Ratio

0 79 79 79 79 77 77 73 73 70 70 66

1 74 72 70 68 70 67 68 65 65 63 60

2 69 65 62 59 64 58 62 57 60 56 53

3 64 59 55 51 58 51 56 50 54 49 47

4 60 53 49 45 53 45 51 44 50 44 42

5 56 49 44 40 48 40 47 40 45 39 38

6 52 44 39 36 44 36 43 35 42 35 34

7 48 41 36 32 40 32 39 32 38 32 30

8 45 37 32 29 37 29 36 29 35 29 27

9 42 34 30 26 34 26 33 26 33 26 25

10 40 32 27 24 32 24 31 24 30 24 23

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 33

Coefficients Of Utilization

Ceiling

80%

70%

50%

30%

0

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room Cavity Ratio

0 78 78 78 78 76 76 73 73 70 70 65

1 74 71 70 68 70 67 67 65 65 63 60

2 69 65 62 60 64 59 62 58 60 56 54

3 65 60 56 53 59 52 57 52 55 51 49

4 61 55 50 47 54 47 52 46 51 46 44

5 57 50 46 42 50 42 48 42 47 41 40

6 53 46 42 38 46 38 45 38 44 37 36

7 50 43 38 35 42 35 41 34 40 34 33

8 47 39 35 32 39 31 38 31 37 31 30

9 44 36 32 29 36 29 35 29 35 29 27

10 41 34 29 27 41 29 34 27 33 26 25

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 28

Candlepower Distribution

Angle

0° CP

0

1482

5

1521

10

1468

15

1354

20

1226

25

1137

30

1017

35

864

40

699

45

538

50

363

55

112

60

13

65

3

70

2

75

1

80

0

85

0

90

0

Candlepower Distribution

Angle

0° CP

0

686

5

719

10

729

15

706

20

697

25

702

30

671

35

601

40

508

45

408

50

306

55

197

60

37

65

4

70

2

75

1

80

0

85

0

90

0

Candlepower Distribution

Angle

0° CP

0

632

5

660

10

666

15

642

20

628

25

625

30

585

35

507

40

403

45

281

50

153

55

57

60

5

65

2

70

1

75

0

80

0

85

0

90

0

SC = 1.1

CERTIFIED TEST REPORT NO. 3278FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**

SC = 1.3

CERTIFIED TEST REPORT NO. 3280FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**

SC = 1.3

CERTIFIED TEST REPORT NO. 3282FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**

181

363

544

725

181

363

544

725

400

800

1200

1600

200

400

600

800

200

400

600

60˚

60˚

60˚

30˚

30˚

30˚

32W G.E. 4 PIN TRIPLE BIAX, LUMEN RATING = 2200 LMS, CL FINISH TRIM

26W G.E. 4 PIN TRIPLE BIAX, LUMEN RATING = 1710 LMS, CL FINISH TRIM