Little wonder hpv vac, Fan removal and installation – Little Wonder HPV 5612-00-01 User Manual

Page 14

Advertising
background image

14

LITTLE

WONDER

HPV VAC

FAN REMOVAL AND INSTALLATION

FAN REMOVAL AND INSTALLATION

Remove spark plug wire from spark plug.

Remove nozzle assembly.

Remove front plate assembly.

Remove the bolt that secures the fan to the engine

crankshaft.

The fan has a 3/4-16 nut welded on fan hub. Turn a 3/4-

16 x 5" long grade 5 (or better) bolt into the nut to jack or

push the fan off the engine. (Schiller Grounds Care, Inc.

P/N 910515 Bolt-Jack Fan is recommended.)

Replace damaged or worn fan with a new one. If during

fan removal the key (#64164-13) was removed from the

keyway, reinstall it by applying a few drops of the Loctite

380 instant adhesive (“Black Max” P/N 38050) on the key,

and load the key in the keyway of the shaft. (Cure time is

approx. 1 min.)

Use a new bolt (#64123-127) (add Loctite 242 to new

bolt) and washer (#910527) and complete fan installation.

Insure a secure fit upon re-assembling. Torque bolt to

39-51 Ft. lbs.

Advertising