P223 flux, Diffusible hydrogen, Packaging – Lincoln Electric P223 FLUX User Manual

Page 3: Typical operating procedures

Advertising
background image

P223 FLUX

AWS A5.17-97: F7A4-EM12K and A5.23-97: F8A2-EA1-A2

P223 Flux 12/03

www.lincolnelectric.com

(mL/100g

weld deposit)

Requirements
AWS F7A4-EM12K

Not Specified

Actual Test Results
P223/L-61

3.7

Requirements
AWS F8A2-EA1-A2

Not Specified

Actual Test Results
P223/L-70

4.2

DIFFUSIBLE HYDROGEN

- As Tested per AWS A4.3-93

Lincolnweld

®

50 lb. (23 kg)

FluxPaper Bag

P223

EDS30636

PACKAGING

Diameter

Approx.

Polarity

Wire Feed

Arc

Travel

CTWD

(1)

Speed

Voltage

Current

Speed

Lead/Trail Spacing

in/min (m/min)

(volts)

(amps)

in/min (m/min)

Side 1

Lead Arc – P223/L-61 or L-70

90 (2.3)

35

920

41 (1.04)

5/32" (4.0 mm)

AC

1-1/2" (38.1 mm)

5/8" (15.88 mm)

Trail Arc – P223/L-61 or L-70

50 (1.3)

36

640

41 (1.04)

5/32" (4.0 mm)

AC

1-1/2" (38.1 mm)

5/8" (15.88 mm)

Side 2

Lead Arc – P223/L-61 or L-70

100 (2.5)

36

980

38 (.97)

5/32" (4.0 mm)

AC

1-1/2" (38.1 mm)

5/8" (15.88 mm)

Trail Arc – P223/L-61 or L-70

48 (1.2)

41

620

38 (.97)

5/32" (4.0 mm)

AC

1-1/2" (38.1 mm)

5/8" (15.88 mm)

(1)

CTWD (Contact Tip to Work Distance). Subtract 1/4" to calculate Electrical Stickout.

[3]

TYPICAL OPERATING PROCEDURES

Two-run seam weld on 0.688" wall X-65 pipe AC/AC two-wire tandem

arc procedure. 0.25" centered land, 90˚ included angle each side, 5˚ push lead arc, 20˚ push angle trail arc.

Advertising