Operation, Avoiding wire feeding problems, Fan control – Lincoln Electric POWER MIG 215 User Manual

Page 18: Input line voltage variations, Wire feed overload protection, Welding thermal overload protection

Advertising
background image

B-6

B-6

OPERATION

9.

When no more welding is to be done, close valve
on gas cylinder (if used), momentarily operate gun
trigger to release gas pressure, and turn off
POWER MIG 215.

NOTE: When using Innershield electrode, the gas

nozzle may be removed from the insulation on
the end of the gun and replaced with the gas-
less nozzle. This will give improved visibility
and eliminate the possibility of the gas nozzle
overheating.

AVOIDING WIRE FEEDING
PROBLEMS

Wire feeding problems can be avoided by observing
the following gun handling procedures:

1. Do not kink or pull cable around sharp corners.
2. Keep the gun cable as straight as possible when

welding or loading electrode through cable.

3. Do not allow dolly wheels or trucks to run over

cables.

4. Keep cable clean by following maintenance instruc-

tions.

5. Use only clean, rust-free electrode. The Lincoln

electrodes have proper surface lubrication.

6. Replace contact tip when the arc starts to become

unstable or the contact tip end is fused or
deformed.

7. Keep wire reel spindle brake tension to minimum

required to prevent excess reel over-travel which
may cause wire “loop-offs” from coil.

8. Use proper drive rolls and wire drive idle roll pres-

sure for wire size and type being used.

FAN CONTROL

The fan is designed to come on when input power is
applied to the POWER MIG 215 and go off when
power is removed.

INPUT LINE VOLTAGE VARIATIONS

High Line Voltage — Higher than rated input voltage
will result in output voltages higher than normal for a
given tap setting. If your input line is high, you may
want to select a lower voltage tap than given on the
recommended procedure chart.

Low Line Voltage — You may not be able to get
maximum output from the machine if the line voltage
is less than rated input. The unit will continue to weld,
but the output may be less than normal for a given tap
setting. If your input line is low, you may want to select
a higher voltage tap than given on the recommended
procedure chart.

WIRE FEED OVERLOAD
PROTECTION

The POWER MIG has solid state overload protection
of the wire drive motor. If the motor becomes over-
loaded, the protection circuitry turns off the wire feed
speed and gas solenoid. Check for proper size tip,
liner, and drive rolls, for any obstructions or bends in
the gun cable, and any other factors that would
impede the wire feeding. to resume welding, simply
pull the trigger. There is no circuit breaker to reset, as
the protection is done with reliable solid state electron-
ics.

WELDING THERMAL OVERLOAD

PROTECTION

The POWER MIG 215 has built-in protective ther-
mostats that respond to excessive temperature. They
open the wire feed and welder output circuits if the
machine exceeds the maximum safe operating tem-
perature because of a frequent overload, or high
ambient temperature plus overload. The thermostats
automatically reset when the temperature reaches a
safe operating level and welding and feeding are
allowed again, when gun is retriggered.

Wire Feed Speed/Voltage Tap Settings

Wire Dia. Gas Type Wire Type Polarity 18 gage 16 gage 14 gage 12 gage10gage 3/16

1/4

5/16

3/8

1/2

Outershield 1" CTWD

.035

75Ar/25CO

2

OS71M

DC+

250/D

300/E

350/F 500/G *500/G

.035

100%CO

2

OS71M

DC+

300/E

350/F 500/G

.045

75Ar/25CO

2

OS71M

DC+

200/E 225/F 250/G 250/G *250/G

Innershield 5/8" CTWD

.035

NoneReq!d NR-211MP

DC-

50/B

70/B

80/B

90/C

100/C

.045

NoneReq!d NR-211MP

DC-

50/B

70/C

90/C 110/D **130/E

.045

NoneReq!d

NR212

DC-

40/B

50/B

60/B

65/C

70/C

90/C 110/D *130/E *150/E *150/E

POWER MIG 215

PROCEDURE CHART

Contact Tip to Work Distance

* Note- Requires Multiple Pass
**.035 & .045 NR-211 MP are only recommended for a maximum steel thickness of 5/16"

Advertising