Lincoln Electric PERKINS SA-250 User Manual

Page 21

Advertising
background image

20

ELECTRONIC IDLER TROUBLESHOOTING GUIDE

Engine Will Not Return to Idle

in Approximately 15 Seconds

Set Idler Control Switch

to the Auto Position

Check to see Whether Oil Pressure

Light is On and Alternator is Charging

Light OFF

Light ON

If Oil Light is O.K., Replace

Check Continuity of Idler

Oil Pressure Switch

Control Switch

Continuity Good

Open

1. Reed Switch in Weld

Replace Switch

Circuit may be Stuck Closed

2. Check Continuity of Idler

Solenoid Coil (25 ohms)

3. Replace P.C. Board

Engine Will Not Pick Up Speed When:

The Arc is Struck

The Auxiliary Power

Load is Turned On

Reed Switch in Weld Circuit

Defective. Will Not Close

Power Load Too Small

Try Load Above 150 Watts

To Check; Short the Red Lead
on P.C. Board to Welder Frame

Engine Does Not Pick Up Speed

Replace P.C. Board

Engine Picks Up

Engine Does Not

Speed When Arc

Pick Up Speed

is Struck

Replace P.C. Board

Replace Reed Switch

in Weld Circuit