Installation, Technical specifications – power mig 200 – Lincoln Electric POWER MIGTM 200 IM693 User Manual

Page 9

Advertising
background image

A-1

A-1

INSTALLATION

75°C Copper Wire

75°C Copper Wire

Input Ampere

in Conduit

in Conduit

Input Voltage/

Fuse or Breaker

Rating On

AWG (IEC) Sizes

AWG (IEC) Sizes

(For lengths

(For lengths

Frequency (Hz)

Size (Super Lag)

Nameplate

up to 100 ft.)

exceeding 100 ft.)

208/50/60

60

36

10 (6 mm

2

)

8 (10 mm

2

)

230/50/60

60

33

10 (6 mm

2

)

8 (10 mm

2

)

NOTE: Use #10 AWG Grounding Wire

TECHNICAL SPECIFICATIONS – POWER MIG 200

INPUT – SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES

Height

Width

Depth

Weight

31.79 in

18.88 in

38.78 in

210 Ibs

808 mm

480 mm

985 mm

95 kg

PHYSICAL DIMENSIONS

Wire Speed

50 – 700 IPM (1.27 – 17.8 m/minute)

WIRE SPEED RANGE

Standard Voltage/Frequency

Input Current @ 150 Amp Rated Output Input Current @ 150 Amp Rated Output

208/230/50/60 Hz

28/26 Amps

36/33

Duty Cycle

Amps

Volts at Rated Amperes

30%

200 Amps

22 Volts

40%

180 Amps

23 Volts

60%

150 Amps

24 Volts

Welding Current Range

Maximum Open Circuit Voltage

Welding Voltage Range

30 – 200 Amps

40 Volts

13.5-22 Volts

POWER MIG 200