Linear ACCESS AK-21 User Manual

Page 7

Advertising
background image

5

PROGRAMMING OPTIONS

There are several AK-21 programming options. For most
installations, the factory set default options are suffi cient. The
keypad must be in Programming Mode to make these changes.

Select Door Sense or Inhibit Input

Default: Door Sense

The input on Terminal Block TB1, Terminal #8 can be programmed for DOOR
SENSE
or INHIBIT.

Press: 1 0 #

Input

#

Input

= 0 for Door Sense, = 1 for Inhibit

When programmed for DOOR SENSE, if an open condition on the input occurs
before access is granted (with an entry code or with the request-to-enter input) a
FORCED ENTRY output will occur. If an open condition remains 60 seconds after
a relay activation for access, a DOOR AJAR output will occur.
When programmed for INHIBIT, a closed condition on the input will prevent
Relay #1 from activating when access is requested with an entry code. This mode
is typically used with an external timer to disable the access device at certain
times.

Select Forced Entry Output

Default: Output #3

Sets which output activates if the DOOR SENSE input opens before access is
granted. This output is not timed.

Press: 1 1 #

Output

#

Output

= Output to Activate (0-4)

1 = Main Relay 2 = Auxiliary Relay 3 = Output #3 4 = Output #4 0 = No Output

Select Door Ajar Output

Default: Output #4

Sets which output activates if the DOOR SENSE input stays open 60 seconds
after access is granted. This output is not timed.

Press: 1 2 #

Output

#

Output

= Output to Activate (0-4)

1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output

Select Keypad Lockout Output

Default: No Output

Sets which output activates when the keypad is “locked out” after too many
incorrect entry code attempts. The lockout time is 60 seconds.

Press: 1 3 #

Output

#

Output

= Output to Activate (0-4)

1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output

Select Keypad Active Output

Default: No Output

Sets which output activates when any keys are pressed. This output is timed. If
toggle mode is selected for the output, the timer value defaults to 2 seconds.

Press: 1 4 #

Output

#

Output

= Output to Activate (0-4)

1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output

Select Alarm Shunt Output

Default: No Output

Sets which output activates during the time access is granted. (Use this output
to shunt alarm contacts attached to the access door.) This output may be timed
or toggled.

Press: 1 5 #

Output

#

Output

= Output to Activate (0-4)

1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output

Select Request-to-Exit Output

Default: Main Relay

Sets which output activates when the Request-to-Exit input is grounded. This
output may be timed or toggled.

Press: 1 6 #

Output

#

Output

= Output to Activate (0-4)

1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output

Main Relay On-time

Default: 2 Seconds

Sets the length of time the Main Relay activates when triggered.

Press: 2 1 #

Seconds

#

Seconds

= Output time in seconds (0-60)

Auxiliary Relay On-time

Default: 2 Seconds

Sets the length of time Auxiliary Relay activates when triggered.

Press: 2 2 #

Seconds

#

Seconds

= Output time in seconds (0-60)

Solid-state Output #3 On-time

Default: 2 Seconds

Sets the length of time Output #3 activates when triggered.

Press: 2 3 #

Seconds

#

Seconds

= Output time in seconds (0-60), 99 = Toggle Mode

Solid-state Output #4 On-time

Default: 2 Seconds

Sets the length of time Output #4 activates when triggered.

Press: 2 4 #

Seconds

#

Seconds

= Output time in seconds (0-60), 99 = Toggle Mode

Set Downlight On-Time

Default: 2 Minutes

Sets the time duration that the downlight remains on after a key press.

Press: 2 5 # Duration #

0 = Always off, 1 = 1 minute, 2 = 2 minutes, 3 = 3 minutes,

4 = 4 minutes, 99 = Always on

Beep Sounds on Keystrokes

Default: Yes

Selects whether or not the keypad beeps as each key is pressed.

Press: 4 0 #

Sound

#

Sound

= 1 for Yes, = 0 for No

Beep Sounds During Main Relay

Default: No

Selects whether or not the keypad beeps during Main Relay activation.

Press: 4 1 #

Sound

#

Sound

= 1 for Yes, = 0 for No

228045 A IMAGE 7