Symptom-to-fru, Index – Lenovo 3000 C100 User Manual

Page 40

Advertising
background image

Symptom

or

error

FRU

or

action,

in

sequence

UNEXPECTED

AMOUNT

OF

MEMORY

-

RUN

SCU

The

size

of

the

system

memory

does

not

match

with

the

CMOS

record.

1.

Reseat

DIMM.

If

the

problem

still

exists,

replace

the

DIMM.

2.

System

board.

CLOCK

NOT

TICKING

CORRECTLY

The

system

clock

is

not

working

correctly.

1.

System

board.

TIME/DATE

CORRUPT

-

RUN

SCU

The

time/date

information

in

CMOS

is

invalid.

1.

Input

date

and

time.

2.

System

board.

MACHINE

IS

LOCKED

-

TURN

KEY

The

keyboard

is

locked.

1.

System

board.

BOOT

SECTOR

0

HAS

CHANGED

The

boot

sector

of

the

hard

disk

has

been

changed,

probably

because

of

a

virus

attack.

1.

Hard

disk

drive.

2.

System

board.

Suspend-to-Disk

partition

MISSING!

No

Suspend-to-Disk

partition

was

found.

1.

Hard

disk

drive.

2.

System

board.

Hard

Disk

ERROR!

Access

to

the

Suspend-to-Disk

partition

failed.

1.

Hard

disk

drive.

2.

System

board.

Suspend-to-Disk

partition

signature

NOT

FOUND!
No

Suspend-to-Disk

partition

signature

was

found.

1.

Hard

disk

drive.

2.

System

board.

Suspend-to-Disk

partition

size

TOO

SMALL!

The

capacity

of

the

Suspend-to-Disk

partition

is

not

adequate.

1.

Hard

disk

drive.

2.

System

board.

MEMORY

SIZE

HAS

CHANGED

--

REBOOTING
The

memory

size

has

changed

since

the

preceding

Suspend-to-

Disk

operation.

1.

Reseat

DIMM.

If

the

problem

still

exists,

replace

the

DIMM.

2.

System

board.

Symptom-to-FRU

index

36

MT

0761

Advertising