4

SERVICE BULLETIN

SEGA Service Department http://www.seuservice.com
45133 Industrial Drive

Phone: 415.701.6580

Fremont, Ca. 94538

Fax: 415.701.6594

If you have any questions please contact the SEGA Service Department at the numbers given above.

120

Feb 9. 2000

The SEGA Naomi Game kits are actually ‘JAMMA Dependent’. What this means exactly is they will only
install into existing JAMMA Cabinets. If an operator tries to install these kits into a Non-JAMMA cabinet,
they will first have to bring the wiring up to JAMMA Standards.

°

Step 1 Disconnect the games original DC Power Supply. You may only use the power supply provided
with your kit. Be sure to set the voltages going to your Game BD to 5.1 and 3.3 volts DC to assure proper
operation ( Measure on Square Connector at Game BD. Yellow = 5vdc / Brown = 3.3vdc / White = Gnd )

°

Step 2 You MUST USE THE COIN METER SUPPLIED WITH YOUR KIT to assure proper Coin

acceptance. A minimum 18 Gauge wire should be used from the Coin Meter 1 output line on your
JAMMA Harness. The 5vdc ( Yellow ) wire found in the wiring bag of your kit MUST BE USED for the
supply voltage to the meter.

SPECIAL NOTICE FOR

ALL SEGA NAOMI KITS

PROBLEM:

SOLUTION:

Not following the directions provided herein may cause your game to malfunction.
All electrical work should be performed by the site’s Serviceman or Technician.

In order to prevent an electric shock and short circuit, be sure to turn power off before performing

work or touching the interior parts of the product.

Be careful so as not to damage wirings. Damaged wiring can cause an electric shock or short circuit

accident.

Do not touch places other than those specified. Touching places not specified can cause an electric

shock or short circuit accident.