Installation, Warning, Dip switch settings and locations – Lincoln Electric POWER WAVE F355I User Manual

Page 12: Control board dip switch, Feed head board dip switch

Advertising
background image

A-5

INSTALLATION

POWER WAVE F355i

A-5

ELECTRIC SHOCK can kill.

• Turn the input power OFF at the

disconnect switch or fuse box
before working on this equipment.

----------------------------------------------------------------------
1. Set the High/Low switch code on Feed Head PC

board as follows:

2.

Turn off power to the power source at the dis-
connect switch.

3. Remove the front cover from the power source.

4. The wire feed head board is on the left side of the

power source. Locate the 8-position DIP switch and
look for position 8 of the DIP switch. (See Figure A.1)

5. Using a pencil or other small object, slide the switch

to the OFF position, when the low speed gear is
installed. Conversely, slide the switch to the ON
position when the high speed gear is installed.

6. Replace the cover and screws. The PC board will

read

the switch at power up, automatically adjust-

ing all control parameters for the speed range
selected.

DIP Switch Settings and Locations

(See Figure A.1)
DIP switches on the P.C. Boards allow for custom
configuration of the Power Wave. To access the DIP
switches:

• Turn off power at the disconnect switch.

------------------------------------------------------------------------

Remove the top four screws securing the front

access panel.

Adjust the DIP switches as necessary.

Replace the panel and screws, and restore power.

Control Board DIP Switch:

switch 1 = Object Instance LSB 1 (see table 1)
switch 2 = Object Instance MSB 2 (see table 1)
switch 3 = Equipment Group 1 Select
switch 4 = Equipment Group 2 Select
switch 5 = Equipment Group 3 Select
switch 6 = Equipment Group 4 Select
switch 7 = reserved for future use
switch 8 = work sense lead
1 LEASE SIGNIFICANT BIT
2 MOST SIGNIFICANT BIT

switch 8

work sense lead

off

work sense lead not connected*

on

work sense lead connected

Feed Head Board DIP Switch:

switch 1 = Object Instance LSB (see table 1)
switch 2 = Object Instance MSB (see table 1)
switch 3 = Equipment Group 1 Select
switch 4 = Equipment Group 2 Select
switch 5 = Equipment Group 3 Select
switch 6 = Equipment Group 4 Select
switch 7 = negative polarity switch

switch 7

electrode polarity

off positive

*

on negative

switch 8 = high speed gear

switch 8

wire drive gear

off

low speed gear *

on

high speed gear

TABLE 1

Object Instance
switch 2

switch 1

Instance

off off

0 *

off

on

1

on off

2

on

on

3

*Factory Setting

WARNING

WARNING

POWER W

AVE F355i

O
N

1

2

3

4

5

6

7

8

O
N

1

2

3

6

5

4

7

8

O
N

1

2

3

4

5

6

7

8

O
N

1

2

3

4

5

6

7

8

LOCATION OF DIP SWITCHES IN MACHINE

CONTROL BOARD DIP SWITCH

FEED HEAD BOARD DIP SWITCH

FIGURE A.1

Advertising