1 controls, Lacie 319 lcd monitor user’s manual, Auto adjust (analog input only) – LaCie 319 User Manual

Page 17: Image controls, Page 17

Advertising
background image

3.1 Controls

page 17

LaCie 319 LCD Monitor

User’s Manual

AUTO BRIGHTNESS

Please keep this function OFF at all times if you are performing color-critical work.
1: Adjusts the brightness automatically, by detecting the brightness level of your environment and adjusting

the monitor with the best BRIGHTNESS setting*1.

2: Adjusts the brightness automatically for the best BRIGHTNESS setting based on the white display area.

The environmental brightness sensor has no function.

OFF:

No function. LaCie recommends this position for calibrated monitor use.

NOTE:

Do not cover environmental brightness sensor.

AUTO

Auto Adjust (Analog input only)

Automatically adjusts the Image Position and H. Size (or V. Size) settings and Fine settings.

Image Controls

LEFT / RIGHT Controls Horizontal Image Position within the display area of the LCD.
DOWN / UP Controls Vertical Image Position within the display area of the LCD.

H. SIZE (OSM ROTATION: Landscape) or V. SIZE (OSM ROTATION: Portrait) (Analog input only)
Adjusts the horizontal (or vertical) size by increasing or decreasing this setting. If the “Auto Adjust function” does not give you
a satisfactory picture setting, a further tuning can be performed manually using the “H. Size (or V. Size)” function (dot clock).
A Moiré test pattern could be used. This function may alter the width of the picture. Use Left/Right Menu to center the image
on the screen. If the H. Size (or V. Size) is wrongly calibrated, the
result would look like the drawing on the left.

FINE (Analog input only)
Improves focus, clarity and image stability by increasing or decreasing this setting. If the “Auto Adjust function” and the
“H.Size” function do not give you a satisfactory picture setting, a fine tuning can be performed using the “Fine” function. It
improves focus, clarity and image stability by increasing or decreasing this setting.
A Moiré test pattern could be used. If the Fine value is wrongly calibrated, the result
would look like the drawing on the left.

When H. SIZE value is

wrong.

When H. SIZE value is

improved.

When H. SIZE value is

correct.

When FINE value is

wrong.

When FINE value is

correct.

Advertising