Troubleshooting, Caution – Lincoln Electric POWER-ARC 4000 User Manual

Page 44

Advertising
background image

E-4

TROUBLESHOOTING

E-4

POWER-ARC 4000

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

Engine will not start.

1. Spark plug boot or wire off, loose or

wet.

2. Fuel shutoff valve is closed.

3. Low oil and engine low oil shutdown

protection will not allow unit to start.
Light in On-Off switch will flash when
engine is cranked. (Engines
equipped with low oil shutdown pro-
tection only).

4. Choke left in full choke position and

carburetor flooded.

5. Fuel line clogged or closed.

6. Recoil start will not engage with

engine.

7. Fouled spark plug.

8. Engine requires service to head,

head gasket, and/or valves.

9.

Float open in carburetor & gas leak-
ing from bowl.

10. Engine operated with low oil level.

Engine is seized and recoil start will
not move.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.

Advertising