Lightolier Arco 4531 User Manual

Is:4531

Advertising
background image

LIGHTOLIER a GENLYTE company.

631 Airport Road, Fall River, MA 02720

(508) 679-8131 • FAX (508) 647-4710

© 1995

Read and understand these instructions before installing fixture.

This fixture is intended for installation in accordance with the National Electrical Code and local or Federal

code specifications. To prevent electric shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

IS:4531

0995

Page 1 of 2

NOTE:

This instruction sheet covers both compact fluorescent and incandescent fixtures. Although illustration shows compact fluorescent, the

incandescent version assembles and installs in the same manner.

NOTE:

The Backplate is provided with (3) Auxiliary Mounting Knockout

Holes (4531, 4532, 4551, and 4552 series fixtures) for direct

mounting to wall surfaces. These can be used for added security or

where direct Outlet Box mounting is not available. To remove plug

in Knockout Holes, follow steps 1 through 3 below.

For 4533 series fixtures, (4) Auxiliary Mounting Knockout Holes

are provided for direct mounting to wall surfaces (no plugs to

remove). It is recommended that Auxiliary Mounting Holes be

used on 4532, 4533 and 4552 series fixtures.

The Backplate can be mounted horizontally of vertically. See Fig 1

below for proper orientation for type of Lens Assembly and desired

position.

1. Position blunt ended punch or awl in center of Knockout hole and

firmly hit with hammer to punch plug through. Repeat for remaining

Knockouts (Fig. 1).

Caution: Always wear eye protection (safety goggles) when

removing Auxiliary Mounting Knock-Outs.

2. Position Backplate in desired position over Outlet Box and mark

location of (4) Auxiliary Holes on wall surface.

3. Determine the appropriate mounting hardware required for type of

wall material fixture is being mounted to (i.e. toggle bolts or molly

screws for plaster or gysum board walls, wood screws, etc.)

4. Thread Crossbar Mounting Screws into Crossbar as shown in

Fig. 1.

5. Using appropriate slots in Crossbar, secure Crossbar to Outlet

Box using Outlet Box Screws (provided with Outlet Box).

6. While supporting Backplate make connections: black fixture lead

or fixture without tracer marks to hot (black) supply lead; white

fixture lead or fixture lead with tracer markers to neutral (white)

supply lead. Un-insulated wire is a ground wire and must be

connected to grounding terminals or ground lead inside Outlet Box.

Use Wire Nuts (local hardware item). Push connections back into

Outlet Box.

FIG.1

Instructions for Installation of Arco™ 4531, 4532, 4533,

4551, and 4552 Series Fixtures.

Wire Nut

Outlet Box

Crossbar

Outlet Box Screws

Ground Wire

Backplate

Gasket

Mounting Hole

Safety Cable

Battery Nut

Loop

Mounting Screw

Lens Assembly

Crossbar Mounting

Screws

Auxiliary Mounting

Knock-out

Position this edge

of Backplate up

for mounting of this

Lens Assembly as shown

Position this edge

of Backplate

up for horizontal

mounting of this

Lens Assembly

Advertising