Installation, Safety precautions, Warning caution – Lincoln Electric COOL ARC IM670-A User Manual

Page 9

Advertising
background image

To avoid freeze damage and water leakage in ship-
ment, the COOL ARC® 40 unit is delivered empty
with no coolant in the system. To fill the unit, locate
the plastic Snap-On reservoir fill cap at the front mid-
dle of the unit. Remove the fill cap by pressing the
center of the cap inward while pulling at the tab on the
outer edge.

Clean tap water, distilled water, de-ionized water, a
50/50 mix of pure ethylene glycol and water, or any
other coolant specified by the manufacturer of the
water cooled product that the Cooler is used with, can
be added into the coolant reservoir. The opening of
the fill cap mates with most coolant containers but, to
avoid spillage of coolant, a funnel should be placed
into the reservoir hole when filling the

COOL ARC®

40.

NOTE: Pure solutions and mixtures of, or materials
(i.e. towels) wetted with ethylene glycol are toxic to
humans and animals. They must not be haphazardly
discarded, especially by pouring liquids down the
drain. Contact the local EPA office for responsible dis-
posal methods or for recycling information.

For best results when using the COOL ARC® 40 with
Lincoln guns or torches, use distilled or de-ionized
water, although if not available, tap water can be
used. If protection from freezing is desired, use a 50%
water and 50% pure ethylene glycol (reagent or
industrial grade) mixture. An alcohol and water mix-
ture is also acceptable.

When using the COOL ARC® 40 with other products,
consult the manufacturer's instruction manual for rec-
ommended coolants.

DO NOT USE OIL BASED COOLANTS OR COOLANTS
THAT CONTAIN RUST INHIBITORS OR LEAK STOP-
PERS.
---------------------------------------------------------------------------

The unit can be filled either vertically or horizontally.
UNPLUG THE COOLER BEFORE FILLING THE
COOLANT RESERVOIR:

UPRIGHT (VERTICAL):
Tilt the unit backward and pour 2 gallons (7.6 liters)

of coolant into the coolant reservoir fill hole through
a funnel.

• If a 1 gallon (3.8 liters) fill bottle is available, tilt the

unit forward until the bottle mates with the coolant
reservoir fill hole. Then tilt the unit backward until the
fill bottle is emptied. Fill the unit with 2 gallons (7.6
liters) of coolant.

A-2

INSTALLATION

COOL ARC® 40

A-2

SAFETY PRECAUTIONS

UNPACKING THE COOL ARC

®

40

The packaging of the Cooler is designed to withstand
shipping abuse, and contains a cardboard liner that
surrounds the unit. If any shipping damage has
occurred, contact your certified Lincoln distributor or
service center. When unpacking the unit, avoid thrust-
ing sharp objects through the carton liner, which may
puncture the plastic reservoir. Below is the recom-
mended procedure for unpacking the Cooler:

• Open top flap where identification label appears.
• Remove loose items and top insert.
• Open bottom flap.
• Remove bottom insert and slide Cooler, wrapped in

inside liner from outer carton.

• Gently remove liner and packaging foam from

Cooler.

Save the instruction manual and service directory sup-
plied with the COOL ARC® 40 for parts orders and
future maintenance service.

FILLING THE COOLANT RESERVOIR

Recommended Coolant
• For Use Above Freezing: Clean tap, distilled or de-

ionized water.

• For Use Below Freezing: 50% water and 50% pure

ethylene glycol (reagent or industrial grade) mixture.

DO NOT USE: Automotive anti-freeze that contains

rust inhibitors or leak stoppers. These coolants will
damage the pump and block the small internal pas-
sageways of the heat exchanger, affecting cooling
performance.

DO NOT USE: Pre-packaged welding industry

coolants. These coolants may contain oil-based
substances, which attack the plastic components of
the cooler. Once added to the cooler, these sub-
stances are virtually impossible to purge from the
water lines and heat exchanger.

ELECTRIC SHOCK

can kill.

• Disconnect input power by remov-

ing plug from receptacle before
working inside Cooler.

• Use only grounded receptacle.

• Do not remove the power cord ground prong.
• Do not touch electrically “hot” parts inside Cooler.
• Have qualified personnel do the installation, main-

tenance and troubleshooting work.

----------------------------------------------------------------------

WARNING

CAUTION

Advertising