4f35, Architectural decorative, Features – Lightolier Architectural Decorative 4F35 User Manual

Page 2: Lamping (by others), Electrical, Mounting, Labels, Application data, Job information type

Advertising
background image

Job Information

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • D0609

Architectural Decorative

4F35

Page 2 of 2

Pendalux Gemini 35” Diameter Body 6-26/32/42 Triple Tube

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD

%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

80

70

50

30

10

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

1

.69 .66 .63 .60 .58 .55 .44 .43 .41 .29 .28 .27 .15 .15 .15 .08

2

.60 .55 .51 .53 .49 .45 .38 .36 .34 .25 .24 .23 .13 .13 .12 .07

3

.53 .47 .43 .46 .42 .38 .34 .31 .28 .22 .21 .19 .12 .11 .10 .06

4

.47 .41 .36 .41 .36 .32 .30 .27 .24 .20 .18 .16 .11 .10 .09 .05

5

.41 .35 .30 .36 .31 .27 .27 .23 .20 .18 .16 .14 .09 .08 .08 .04

6

.37 .31 .26 .32 .27 .23 .24 .20 .18 .16 .14 .12 .08 .07 .07 .04

7

.33 .27 .22 .29 .24 .20 .21 .18 .15 .14 .12 .10 .08 .06 .06 .03

8

.30 .24 .20 .26 .21 .17 .19 .16 .13 .13 .11 .09 .07 .06 .05 .03

9

.27 .21 .17 .23 .19 .15 .17 .14 .12 .12 .10 .08 .06 .05 .04 .02

10

.24 .19 .15 .21 .17 .13 .16 .13 .10 .11 .08 .07 .06 .05 .04 .02

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

ANGLE MEAN CP LUMENS

0

826

5

824

78

10

814

15

798

226

20

184

25

776

346

30

748

35

715

422

40

675

45

626

443

50

574

55

517

409

60

456

65

396

332

70

334

75

273

230

80

216

85

164

137

90

97

CERTIFIED TEST REPORT NO. 1409FR

COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE

CAT. #4F35642WHU, 35” DIFFUSER WITH SPILL RING

6-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS.

ADVANCE BALLAST #ICF-2S42-M2-LD, 120VAC

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

649

3.38

4.08

0-40

1072

5.58

6.74

0-60

1925

10.03

12.09

0-90

2623

13.67

16.48

40-90

1551

8.08

9.75

60-90

698

3.64

4.39

90-180

13294

69.24

83.52

0-180

15917

82.91

100.00

** EFFICIENCY = 82.9% **

ANGLE MEAN CP LUMENS

90

97

95

390

536

100

1088

105

1551

1620

110

1934

115

2246

2218

120

2511

125

2646

2362

130

2729

135

2835

2195

140

2940

145

3004

1880

150

3022

155

3055

1415

160

3096

165

2936

820

170

2602

175

2537

249

180

2749

C

ANDLEPOWER SUMMARY

ZONAL LUMENS AND PERCENTAGES

DATE: MAY 4, 2001
PREPARED FOR:
LIGHTOLIER, FALL RIVER, MA

Features

1. Diffusing Reflector: White translucent acrylic, 3/16” thick.
2. Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3. Chassis: Steel 20 gauge, semi-gloss white powder-coat finish.
4. Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia.

fastened internally, no exposed hardware. Permits installation on ceilings
with slope of up to 45°. Complies with California Code.

5. Multiple Stems: 3/8” Steel outer pipe stems surround center stem and go

into collector plate.

6. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or

GX24q-4 lamp base.

7. Flange Trim: Steel 20 gauge, Plated or Painted Finish.

Lamping (by others)

Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.

General Electric

Osram/Sylvania

Philips

26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp

F26TBX/*/A/4P

CF26DT/E/IN/*

PL-T26W/*/4P

32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp

F32TBX/*/A/4P

CF32DT/E/IN/*

PL-T32W/*/4P

42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp

F42QBK/*/A/4P

CF42DT/E/IN/*

PL-T42W/*/4P

*Manufacturers’ color temperature designation.

Electrical

Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start.
Universal Voltage 120/277V, Multi-Wattage 26/32/42W.

6 Lamps

26 Watt

32Watt

42Watt

Voltage

120V 277V 120V 277V

120V 277V

Total Input Watts

165

165

204

204

279 279

Max. Line Current (amps) 2.22 0.96 2.80 1.20

1.20 1.60

Power Factor

>0.98 >0.98 >0.98 >0.98 >0.99 >0.99

Ballast Factor

1.02 1.02 0.96 0.96

0.95 0.95

THD<10% Minimum Starting Temperature -5°F /-20°C.

Mounting

Mounts directly to 4” outlet box, using crossbar hanger, supplied.

Labels

cULus listed suitable for damp locations.

Application Data

Reflectancies: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75 (.88 BF x .85)
FC (footcandles) at 30” work plane.

35 Inch Diameter
36’ x 36’ x 11’ Space
Luminaire

Spacing: 12’ x 12’

Susp. Dist. 35”

6 Lamps

26W

32W

42W

TTT

TTT

TTT

Illum. (FC)

33

44

60

Maint.
Lum.

8/1

8/1

7/1

Ratio
Watts/

1.15

1.42

1.94

Sq. Ft.

Advertising