READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE

This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To

assure full compliance with local codes and regulations, check with your local electrical inspector before

installation. To prevent electric shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

INSTALLATION PROCEDURE FOR ELLIPSOIDAL DOWNLIGHT

(TUNGSTEN-HALOGEN)

CAUTION: (RISK OF FIRE)

DO NOT INSTALL INSULATION ABOVE, NOR WITHIN 24 INCHES (610mm) OF ANY PART

OF THE LUMINAIRE.

INSTRUCTION SHEET NO.

A0302

Page 1 of 3

A

COMPANY

631 Airport Road, Fall River, MA 02720

INSTALL WITH FOLLOWING MINIMUM SPACINGS BETWEEN

(A) CENTER-TO-CENTER OF ADJACENT LUMINAIRES: 48 INCHES (1219mm);

(B) TOP OF LUMINAIRE TO OVERHEAD BUILDING MEMBER:

*

INCHES (

*

mm);

(C)

LUMINAIRE CENTER TO SIDE BUILDING MEMBER: 24 INCHES (610mm).

*

FOR 7082, 6 INCHES (152mm)

*

FOR 7084, 3 INCHES (76mm)

A. INSTALL MOUNTING FRAME IN CEILING

USING ADJUSTABLE

MOUNTING BRACKET

(1) With MOUNTING BARS (order separately):

18” – Cat. No. 1950; 27” – Cat. No 1951).
Use rectangular slots as shown.

(3) With 1 ½” channel (by others)

Slide MOUNTING BARS or CHANNELS (by others) through slots in ADJUSTABLE MOUNTING BRACKET which will place the
bottom of the MOUNTING FRAME approximately in line with the finished ceiling line. Final adjustments may be made by means of
MOUNTING BRACKET SCREWS on inside of fixture.

FIG. 1

FIG. 3

FIG. 2

FIG. 4

(2) With ¾” channel (by others)