Operation, Wfs calibration with digital meters – Lincoln Electric LN- 25 PIPE IM10056 User Manual

Page 21

Advertising
background image

b-5

OPERATION

b-5

LN™-25 PIPE

Wire Feed Speed Units
To change the wire feed speed units:

Rotate the WFS knob to
the

left

to

use

“inches/minute” for the
wire feed speed units.

Rotate the WFS knob to
the

right

to

use

“meters/minute” for the
wire feed speed units.

Then rotate the WFS knob
to the 12 o’clock position.

Press the set-up button again to enter the Run-In
menu.

RUN-IN

“Run-in” refers to the wire feed speed during the time
from when the trigger is pulled to when an arc is
struck.

When Run-in is “ON”, the wire feed speed is reduced
until an arc is struck. Factory setting is Run-In “OFF”.

Model

Run-in Wire Feed Speed

Extra Torque Models

25 in/min

Standard Speed Models

50 in/min

When Run-in is “OFF”, the wire feed speed is the
same as the welding wire feed speed. Turn Run-In
“OFF” for fast, crisp starts, especially when running
with .035 or .045 (0.9 or 1.2mm) solid steel wires at
high wire feed speeds.

US

V

A

O O

O O WFS

LN™-25 PIPE

US

V

A

O O

O O WFS

LN™-25 PIPE

U o

r

E

V

A

O O

O O WFS

LN™-25 PIPE

U o

r

E

V

A

O O

O O WFS

LN™-25 PIPE

To change the Run-in setting:

Rotate the WFS knob to
the left to turn Run-In
OFF.

Rotate the WFS knob to
the right to turn Run-In ON.

Then rotate the WFS knob
to the 12 o’clock position.

Press the set-up button again to enter the WFS cali-
bration menu.

WFS CALIbRATION WITH DIGITAL
METERS

To calibrate the wire feed speed, before entering the
set-up menu:

Set the display to the desired wire feed speed
(example: 400 inches per minute)

Measure the actual wire feed speed (example: 405
inches per minute)

While in the set-up menu, adjust the calibration factor
as follows:

Actual WFS

405

Set WFS

400

Press the set-up button.

r

O

V

A

O O

O O WFS

LN™-25 PIPE

u n

n

r

O

V

A

O O

O O WFS

LN™-25 PIPE

u n

n

r

OF F

u n

V

A

O O

O O WFS

LN™-25 PIPE

r

OF F

u n

V

A

O O

O O WFS

LN™-25 PIPE

=Calibration Factor Example

=1.01