LG SINGLE LINE TELEPHONE LKA-200 User Manual

Page 6

Advertising
background image

Issue 1 Jan 2006

LKA-200

_________________________________________________________________________________________________

_____________________________________________________________________________

6

6.4 DC CHARACTERISTICS

6.4.1 on-hook AC impedance

Required result:

f < 200 Hz :

More than

25 kohm

697 < f < 1,633 Hz :

More than

80 kohm

f > 3,200

Hz :

More than

60 kohm


6.4.2 off-hook AC impedance

Required result: 400 ~ 1,400 ohm

6.4.3 Return Loss

Required result: More than 10 dB through frequency range 200 ~ 3,200 Hz



6.5
CALL ALERTING CHARACTERISTICS

6.5.1 Minimum Ring Start Voltage

Required result: 20 ~ 40 Vrms at 20 Hz (typical 27 Vrms)

6.5.2 Ring sound level

Required result: (at distance 50 cm for ring signal 20 Hz 70 Vrms)

Maximum level :

more than 70 dBspl.


6.5.3 Message Waiting Indicator

Required result: Minimum level 70 Vdc for MWI operation.


6.6 RELIABILITY TEST

6.6.1 Temperature test

Required result:

No operation error occurs during each condition;

1) Setup chamber in 0

0

C for 12 hours

2) Setup chamber in 40

0

C at R.H. 85% for 12 hours

Advertising